Optimization of the flip angles of narrow-band editing pulses in J-difference edited MRS of lactate at 3T.

Jason E Moore, Ryan K Robison, Jie Hu, Saikat T Sengupta, Olaimatu S Mahdi, Adam W Anderson, Leo Y Luo, Alexander C Mohler, Ryan T Merrell, Changho Choi

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jason E MooreVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Ryan K RobisonVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Jie HuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Saikat T SenguptaVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.ORCID 0000-0001-5032-006X
Olaimatu S MahdiVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.ORCID 0000-0003-1830-5411
Adam W AndersonVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Leo Y LuoDepartment of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Alexander C MohlerDepartment of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Ryan T MerrellDepartment of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
Changho ChoiVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.ORCID 0000-0002-7135-2447

Funding

Biophysical basis of functional MRI of white matterR01NS113832 · NINDS · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2020 to 2024
$2.4M
Replacement and Upgrade of a 3T MR Scanner for ResearchS10OD021771 · OD · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GORE, JOHN C · 2016 to 2016
$2.0M
NIH HHS S10 OD021771NIH HHS S10OD021771-01NINDS NIH HHS R01 NS113832
6 · The paper itself

Abstract

purposeApplication of highly selective editing RF pulses provides a means of minimizing co-editing of contaminants in J-difference MRS (MEGA), but it causes reduction in editing yield. We examined the flip angles (FAs) of narrow-band editing pulses to maximize the lactate edited signal with minimal co-editing of threonine.

methodsThe effect of editing-pulse FA on the editing performance was examined, with numerical and phantom analyses, for bandwidths of 17.6-300 Hz in MEGA-PRESS editing of lactate at 3T. The FA and envelope of 46 ms Gaussian editing pulses were tailored to maximize the lactate edited signal at 1.3 ppm and minimize co-editing of threonine. The optimized editing-pulse FA MEGA scheme was tested in brain tumor patients.

resultsSimulation and phantom data indicated that the optimum FA of MEGA editing pulses is progressively larger than 180° as the editing-pulse bandwidth decreases. For 46 ms long 17.6 Hz bandwidth Gaussian pulses and other given sequence parameters, the lactate edited signal was maximum at the first and second editing-pulse FAs of 241° and 249°, respectively. The edit-on and difference-edited lactate peak areas of the optimized FA MEGA were greater by 43% and 25% compared to the 180°-FA MEGA, respectively. In-vivo data confirmed the simulation and phantom results. The lesions of the brain tumor patients showed elevated lactate and physiological levels of threonine.

conclusionThe lactate MEGA editing yield is significantly increased with editing-pulse FA much larger than 180° when the editing-pulse bandwidth is comparable to the lactate quartet frequency width.

Indexed as

Brain NeoplasmsLactic AcidHumansMagnetic Resonance SpectroscopyPhantoms, ImagingThreonineLactic AcidThreonine1H MRS3Tediting-pulse flip angle (FA)lactateMEGA J-difference editing

Identifiers

PMID38010083
PMCPMC10929535

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.