Evidence map›Paper›PMID 38009992›Full record

ArticleMagnetic resonance in medicine2024

Adjustment of rotation and saturation effects (AROSE) for CEST imaging.

Tao Jin, Julius Juhyun Chung

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Inverting CEST orMagnetic resonance in medicine · 2026
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tao JinDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.ORCID 0000-0003-2912-3517
Julius Juhyun ChungDepartment of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.ORCID 0000-0002-1513-5181

Funding

Magnetic Resonance Imaging of Glucose Analogs in StrokeR01NS100703 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI JIN, TAO · 2018 to 2022
$1.6M
NIH HHS R01-NS100703NINDS NIH HHS R01 NS100703
6 · The paper itself

Abstract

purposeEndogenous CEST signal usually has low specificity due to contaminations from the magnetization transfer contrast (MTC) and other labile protons with overlapping or close Larmor frequencies. We propose to improve CEST signal specificity with adjustment of rotation and saturation effects (AROSE).

methodsThe AROSE approach measures the difference between CEST signals acquired with the same average irradiation power but largely different duty cycles, for example, a continuous wave or a high duty cycle pulse train versus a low duty cycle pulse train with a flip angle φ. Simulation, phantom, and in vivo rodent studies were performed to evaluate the characteristics of the AROSE

resultsSimulation and experimental results show that AROSE

conclusionCompared to conventional CEST signals, AROSE can minimize MTC and improve exchange rate filtering and Larmor frequency specificity.

Indexed as

Magnetic Resonance ImagingProtonsImage Interpretation, Computer-AssistedPhantoms, ImagingRotationProtonsCESTcontinuous waveexchange rate filterLarmor frequency specificitypulse trainrotation transfer

Identifiers

PMID38009992
PMCPMC10841829

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.