Evidence map›Paper›PMID 38007426›Full record

Observational studyBMC anesthesiology2023

Positional relationships between a tracheal diverticulum and the tracheal tube under general anesthesia: a single-center observational and simulation study.

Kunihiro Mitsuzawa, Tsukasa Kumagai, Haruo Uchida, Toshiyuki Shimizu

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in BMC anesthesiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Kunihiro MitsuzawaDepartment of Anesthesiology and Resuscitology, Shinshu University School of Medicine, 3-1-1, Asahi, Matsumoto City, Nagano, 390-8621, Japan. mitsukuni@shinshu-u.ac.jp.
Tsukasa KumagaiDepartment of Anesthesiology, Nagano Prefectural Shinshu Medical Center, 1332, Suzaka City, Nagano, 382-8577, Japan.
Haruo UchidaDepartment of Anesthesiology, Nagano Prefectural Shinshu Medical Center, 1332, Suzaka City, Nagano, 382-8577, Japan.
Toshiyuki ShimizuDepartment of Anesthesiology, Nagano Prefectural Shinshu Medical Center, 1332, Suzaka City, Nagano, 382-8577, Japan.
Nagano Prefectural Suzaka Hospital · JPShinshu University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIncomplete sealing of tracheal diverticula by a tracheal tube cuff during positive-pressure ventilation causes barotrauma but the concrete possibility of incomplete sealing has not been indicated. We aimed to assess the possibility of incomplete sealing in a simulated situation of tracheal intubation for patients with tracheal diverticula with tube fixation where the tracheal tube's vocal cord guide overlaps with the patient's vocal cord.

methodsWe retrospectively assessed the characteristics of tracheal diverticula based on thoracic computed tomography data in our institution from January 2018 to July 2020. Then, we assessed the structural parameters of three single-lumen tracheal tubes (Parker Flex-Tip [Parker Medical, Bridgewater, CT, USA], Portex Soft Seal [ICU Medical, San Clemente, CA, USA], and Shiley TaperGuard [Medtronic, Dublin, Ireland]; 6.0-8.0 mm inner diameter size) and simulated the positional relationships between tracheal diverticula and the tracheal tube during tracheal intubation where the vocal cord guide overlaps with the patient's vocal cord. We assessed each tube product's possibility of incompletely sealing tracheal diverticula and the possibility of unintended bronchial intubation.

resultsIn 5,854 patients, the prevalence of tracheal diverticula was 5.7%. The mean (SD) length from the vocal cord to the distal end of the tracheal diverticula was 52.2 (12.8) mm. Tracheal tubes with length from the distal end of the tracheal cuff to the vocal cord guide of ≥ 70 mm had a low risk of incompletely sealing tracheal diverticula (< 5%) and length from the distal end of the tube to the vocal cord guide of ≤ 95 mm had a low risk of unintended bronchial intubation (< 5%). No products in this study satisfied both outcomes.

conclusionsTube fixation, where the vocal cord guide overlaps with the patient's vocal cord, is associated with risk of incompletely sealing of tracheal diverticula depending on the tube's manufacturer and tube's inner diameter size, although it was not a high risk. The use of small inner diameter sized tube relative to patient's body size is high risk of incomplete sealing of tracheal diverticula.

trial registrationThis trial was prospectively registered at University Hospital Medical Information Network (UMIN). CLINICAL TRIAL NUMBER AND REGISTRY URL: UMIN000043317 (URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000048055 ).

Indexed as

DiverticulumTracheal DiseasesAnesthesia, GeneralHumansIntubation, IntratrachealRespiration, ArtificialRetrospective StudiesBronchial intubationMalposition of tracheal tubeTracheal diverticulumTracheal intubationTracheal tube

Identifiers

PMID38007426
PMCPMC10675875
OpenAlexW4389002068

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.