Evidence map›Paper›PMID 38006137›Full record

ArticlePolymers2023

Progress on a Novel, 3D-Printable Heart Valve Prosthesis.

Filip Schröter, Ralf-Uwe Kühnel, Martin Hartrumpf, Roya Ostovar, Johannes Maximilian Albes

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Filip SchröterDepartment of Cardiovascular Surgery, Heart Center Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.ORCID 0000-0002-9625-3066
Ralf-Uwe KühnelDepartment of Cardiovascular Surgery, Heart Center Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
Martin HartrumpfDepartment of Cardiovascular Surgery, Heart Center Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.ORCID 0000-0003-1889-6039
Roya OstovarDepartment of Cardiovascular Surgery, Heart Center Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.
Johannes Maximilian AlbesDepartment of Cardiovascular Surgery, Heart Center Brandenburg, Brandenburg Medical School Theodor Fontane, 14770 Brandenburg an der Havel, Germany.ORCID 0000-0003-4722-3896
Universitätsklinikum Brandenburg an der Havel · DEUniversity of Applied Sciences Potsdam · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Polymeric heart valves are prostheses constructed out of flexible, synthetic materials to combine the advantageous hemodynamics of biological valves with the longevity of mechanical valves. This idea from the early days of heart valve prosthetics has experienced a renaissance in recent years due to advances in polymer science. Here, we present progress on a novel, 3D-printable aortic valve prosthesis, the TIPI valve, removing the foldable metal leaflet restrictor structure in its center. Our aim is to create a competitive alternative to current valve prostheses made from flexible polymers. (2) Methods: Three-dimensional (3D) prototypes were designed and subsequently printed in silicone. Hemodynamic performance was measured with an HKP 2.0 hemodynamic testing device using an aortic valve bioprosthesis (BP), a mechanical prosthesis (MP), and the previously published prototype (TIPI 2.2) as benchmarks. (3) Results: The latest prototype (TIPI 3.4) showed improved performance in terms of regurgitation fraction (TIPI 3.4: 15.2 ± 3.7%, TIPI 2.2: 36.6 ± 5.0%, BP: 8.8 ± 0.3%, MP: 13.2 ± 0.7%), systolic pressure gradient (TIPI 3.4: 11.0 ± 2.7 mmHg, TIPI 2.2: 12.8 ± 2.2 mmHg, BP: 8.2 ± 0.9 mmHg, MP: 10.5 ± 0.6 mmHg), and effective orifice area (EOA, TIPI 3.4: 1.39 cm

Indexed as

3D printingaortic valve prosthesispolymeric heart valves

Identifiers

PMID38006137
PMCPMC10674413
OpenAlexW4388694879

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.