Evidence map›Paper›PMID 38005671›Full record

ArticleSensors (Basel, Switzerland)2023

Measuring Heat Stress for Human Health in Cities: A Low-Cost Prototype Tested in a District of Valencia, Spain.

Àlex Aduna-Sánchez, Antonio Correcher, David Alfonso-Solar, Carlos Vargas-Salgado

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Àlex Aduna-SánchezInstitute for Energy Engineering, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain.
Antonio CorrecherInstituto de Automática e Informática Industrial, Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0002-2443-9857
David Alfonso-SolarInstitute for Energy Engineering, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0003-0141-075X
Carlos Vargas-SalgadoInstitute for Energy Engineering, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain.ORCID 0000-0002-9259-8374

Funding

European Union Horizon 2020 research and innovation programme under the project Green Cities for Climate and Water Resilience, Sustainable Economic Growth, Healthy Citizens and Environments (GROW-GREEN) with reference 730283
6 · The paper itself

Abstract

Nowadays, the measurement of heat stress indices is of principal importance due to the escalating impact of global warming. As temperatures continue to rise, the well-being and health of individuals are increasingly at risk, which can lead to a detrimental effect on human performance and behavior. Hence, monitoring and assessing heat stress indices have become necessary for ensuring the safety and comfort of individuals. Thermal comfort indices, such as wet-bulb globe temperature (WBGT), Tropical Summer Index (TSI), and Predicted Heat Strain (PHS), as well as parameters like mean radiant temperature (MRT), are typically used for assessing and controlling heat stress conditions in working and urban environments. Therefore, measurement and monitoring of these parameters should be obtained for any environment in which people are constantly exposed. Modern cities collect and publish this relevant information following the Smart City concept. To monitor large cities, cost-effective solutions must be developed. This work presents the results of a Heat Stress Monitoring (HSM) system prototype network tested in the Benicalap-Ciutat Fallera district in Valencia, Spain. The scope of this work is to design, commission, and test a low-cost prototype that is able to measure heat stress indices. The Heat Stress Monitoring system comprises a central unit or receiver and several transmitters communicating via radiofrequency. The transmitter accurately measures wind speed, air temperature, relative humidity, atmospheric pressure, solar irradiation, and black globe temperature. The receiver has a 4G modem that sends the data to an SQL database in the cloud. The devices were tested over one year, showing that radio data transmission is reliable up to 700 m from the receiver. The system's power supply, composed of a Photovoltaic panel and Lithium-ion batteries, provided off-grid capabilities to the transmitter, with a tested backup autonomy of up to 36 days per charge. Then, indicators such as WBGT, TSI, and MRT were successfully estimated using the data collected by the devices. The material cost of a 12-point network is around EUR 2430 with a competitive price of EUR 190 per device.

Indexed as

Heat Stress DisordersCitiesHeat-Shock ResponseHot TemperatureHumansHumiditySpainTemperatureArduinoheat stresslow-costMRTPHSsmart cityTSIWBGT

Identifiers

PMID38005671
PMCPMC10674217

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.