ArticleSensors (Basel, Switzerland)2023
Improved U-Net Model to Estimate Cardiac Output Based on Photoplethysmography and Arterial Pressure Waveform.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Measuring cardiac stroke volume through in-ear audio sensing.Nature communications · 2026Article
- A Novel Method for Cardiac Output and Vascular Parameters Estimation Using Peripheral Arterial Waveforms: Integrating Windkessel Model viaAnnals of biomedical engineering · 2026Article
- A Machine learning pipeline to investigate tissue ingrowth in cerebral aneurysms using preclinical animal models.Scientific reports · 2026Article
- Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients.Sensors (Basel, Switzerland) · 2026Article
- Predicting in-hospital indicators from wearable-derived signals for cardiovascular and respiratory disease monitoring: An in silico study.PLOS digital health · 2025Article
- Machine learning-enabled estimation of cardiac output from peripheral waveforms is independent of blood pressure measurement location in an in silico population.Scientific reports · 2025Article
- Machine Learning-Based Cardiac Output Estimation Using Photoplethysmography in Off-Pump Coronary Artery Bypass Surgery.Journal of clinical medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We aimed to estimate cardiac output (CO) from photoplethysmography (PPG) and the arterial pressure waveform (ART) using a deep learning approach, which is minimally invasive, does not require patient demographic information, and is operator-independent, eliminating the need to artificially extract a feature of the waveform by implementing a traditional formula. We aimed to present an alternative to measuring cardiac output with greater accuracy for a wider range of patients. Using a publicly available dataset, we selected 543 eligible patients and divided them into test and training sets after preprocessing. The data consisted of PPG and ART waveforms containing 2048 points with the corresponding CO. We achieved an improvement based on the U-Net modeling framework and built a two-channel deep learning model to automatically extract the waveform features to estimate the CO in the dataset as the reference, acquired using the EV1000, a commercially available instrument. The model demonstrated strong consistency with the reference values on the test dataset. The mean CO was 5.01 ± 1.60 L/min and 4.98 ± 1.59 L/min for the reference value and the predicted value, respectively. The average bias was -0.04 L/min with a -1.025 and 0.944 L/min 95% limit of agreement (LOA). The bias was 0.79% with a 95% LOA between -20.4% and 18.8% when calculating the percentage of the difference from the reference. The normalized root-mean-squared error (RMSNE) was 10.0%. The Pearson correlation coefficient (r) was 0.951. The percentage error (PE) was 19.5%, being below 30%. These results surpassed the performance of traditional formula-based calculation methods, meeting clinical acceptability standards. We propose a dual-channel, improved U-Net deep learning model for estimating cardiac output, demonstrating excellent and consistent results. This method offers a superior reference method for assessing cardiac output in cases where it is unnecessary to employ specialized cardiac output measurement devices or when patients are not suitable for pulmonary-artery-catheter-based measurements, providing a viable alternative solution.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.