Evidence map›Paper›PMID 38004964›Full record

ArticleMicromachines2023

Design and Experimental Evaluation of a Dual-Cantilever Piezoelectric Film Sensor with a Broadband Response and High Sensitivity.

Wei Xin, Zhaoyang He, Chaocheng Zhao

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Wei XinCollege of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
Zhaoyang HeCollege of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.
Chaocheng ZhaoCollege of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China.

Funding

Horizontal Project H2020009
6 · The paper itself

Abstract

Cantilever-beam-type PVDF (Polyvinylidene Fluoride) piezoelectric film sensors are commonly utilized for vibration signal detection due to their simple structures and ease of processing. Traditional cantilevered PVDF piezoelectric film sensors are susceptible to the influence of the second-order vibration mode and have a low lateral stress distribution at the free end, which limit their measurement bandwidth and sensitivity. This study is on the design of a dual-cantilever PVDF piezoelectric film sensor based on the principle of cantilevered piezoelectric film sensors. The results of the experiments indicate that, compared to a typical single-arm piezoelectric cantilever beam vibration sensor, the developed sensor has a longer second-order natural frequency that ranges from 112 Hz to 453 Hz, while the first-order natural frequency is maintained at around 12 Hz. This leads to a better ratio of the second-order natural frequency to the first-order natural frequency and a wider frequency response range. At the same time, the sensitivity is increased by a factor of 3.48.

Indexed as

cantilever beamdual-arm structuremeasurement bandwidthnatural frequencyPVDF piezoelectric filmsensitivity

Identifiers

PMID38004964
PMCPMC10673016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.