Evidence map›Paper›PMID 38004868›Full record

ArticleMicromachines2023

Pneumatic Microballoons for Active Control of the Vibration-Induced Flow.

Taku Sato, Kanji Kaneko, Takeshi Hayakawa, Hiroaki Suzuki

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Taku SatoDepartment of Precision Mechanics, Faculty of Science and Engineering, Chuo University, Tokyo 112-8551, Japan.
Kanji KanekoDepartment of Precision Mechanics, Faculty of Science and Engineering, Chuo University, Tokyo 112-8551, Japan.
Takeshi HayakawaDepartment of Precision Mechanics, Faculty of Science and Engineering, Chuo University, Tokyo 112-8551, Japan.ORCID 0000-0002-8420-3758
Hiroaki SuzukiDepartment of Precision Mechanics, Faculty of Science and Engineering, Chuo University, Tokyo 112-8551, Japan.ORCID 0000-0002-8899-0955

Funding

Japan Society for the Promotion of Science 19H02115, 19H00901, 20H05935, 22H01454, 23KJ1940the Institute of Science and Engineering, Chuo University N/Athe Japan Keirin Autorace Foundation (JKA) N/A
6 · The paper itself

Abstract

Vibration-induced flow (VIF), in which a mean flow is induced around a microstructure by applying periodic vibrations, is increasingly used as an active flow-control technique at the microscale. In this study, we have developed a microdevice that actively controls the VIF patterns using elastic membrane protrusions (microballoons) actuated by pneumatic pressure. This device enables on-demand spatial and temporal fluid manipulation using a single device that cannot be achieved using a conventional fixed-structure arrangement. We successfully demonstrated that the device achieved displacements of up to 38 µm using the device within a pressure range of 0 to 30 kPa, indicating the suitability of the device for microfluidic applications. Using this active microballoon array, we demonstrated that the device can actively manipulate the flow field and induce swirling flows. Furthermore, we achieved selective actuation of the microballoon using this system. By applying air pressure from a multi-input channel system through a connection tube, the microballoons corresponding to each air channel can be selectively actuated. This enabled precise control of the flow field and periodic switching of the flow patterns using a single chip. In summary, the proposed microdevice provides active control of VIF patterns and has potential applications in advanced microfluidics, such as fluid mixing and particle manipulation.

Indexed as

active flow controlmicroballoonsmicropillarspneumatic actuatorvibration-induced flow

Identifiers

PMID38004868
PMCPMC10673574

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.