Evidence map›Paper›PMID 38002617›Full record

ArticleJournal of clinical medicine2023

Feasibility and Safety Study of Concomitant Left Bundle Branch Area Pacing and Atrioventricular Node Ablation with Same-Day Hospital Dismissal.

Zhigang Liu, Xiaoke Liu

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Same-day discharge after electrophysiological and cardiac implantable electronic device procedures: a clinical consensus statement of the European Heart Rhythm Association (EHRA) and the Association of Cardiovascular Nursing & Allied Professions (ACNAP) of the ESC.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Zhigang LiuDepartment of Cardiology, Ascension Borgess Hospital, Kalamazoo, MI 49048, USA.
Xiaoke LiuDepartment of Cardiovascular Medicine, Mayo Clinic Health System, La Crosse, WI 54601, USA.ORCID 0000-0003-4782-0957

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft bundle branch area pacing (LBBAP) has rapidly emerged as a promising modality of physiologic pacing and has demonstrated excellent lead stability. In this retrospective study, we evaluate whether this pacing modality can allow concomitant atrioventricular node (AVN) ablation and same-day dismissal.

methodsTwenty-four consecutive patients (female 63%, male 37%) with an average age of 78 ± 5 years were admitted for pacemaker (75%)/defibrillator (25%) implantations and concomitant AVN ablation. Device implantation with LBBAP was performed first, followed by concomitant AVN ablation through left axillary vein access to allow for quicker post-procedure ambulation. The patients were discharged on the same day after satisfactory post-ambulation device checks.

resultsLBBAP was successful in 22 patients (92% in total, 20 patients had an LBBP and two patients had a likely LBBP), followed by AVN ablation from left axillary vein access (21/24, 88%). All patients had successful post-op chest x-rays, post-ambulation device checks, and were discharged on the same day. After a mean follow up of three months, no major complications occurred, such as LBBA lead dislodgement requiring a lead revision. The LBBA lead pacing parameters immediately after implantation vs. three-month follow up were a capture threshold of 0.8 ± 0.3 V@0.4 ms vs. 0.6 ± 0.3 V@0.4 ms, sensing 9.9 ± 3.9 mV vs. 10.4 ± 4.1 mV, and impedance of 710 ± 216 ohm vs. 544 ± 110 ohm. The QRS duration before and after AVN ablation was 117 ± 32 ms vs. 123 ± 14 ms. Mean LVEF before and three months after the implantation was 44 ± 14% vs. 46 ± 12%.

conclusionLBBA pacing not only offers physiologic pacing, but also allows for a concomitant AVN ablation approach from the left axillary vein and safe same-day hospital dismissal.

Indexed as

atrial fibrillationatrioventricular node ablationaxillary vein accessleft bundle branch area pacingsame-day dismissal

Identifiers

PMID38002617
PMCPMC10672577

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.