Evidence map›Paper›PMID 38002414›Full record

ArticleBioengineering (Basel, Switzerland)2023

A Novel Registration Method for a Mixed Reality Navigation System Based on a Laser Crosshair Simulator: A Technical Note.

Ziyu Qi, Miriam H A Bopp, Christopher Nimsky, Xiaolei Chen, Xinghua Xu, Qun Wang, Zhichao Gan, Shiyu Zhang, Jingyue Wang, Haitao Jin and 1 more

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ziyu QiDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.ORCID 0000-0001-5318-3881
Miriam H A BoppDepartment of Neurosurgery, University of Marburg, Baldingerstrasse, 35043 Marburg, Germany.ORCID 0000-0003-1574-7572
Christopher NimskyDepartment of Neurosurgery, University of Marburg, Baldingerstrasse, 35043 Marburg, Germany.ORCID 0000-0002-8216-9410
Xiaolei ChenDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Xinghua XuDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Qun WangDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Zhichao GanDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Shiyu ZhangDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Jingyue WangDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.ORCID 0000-0001-9671-2245
Haitao JinDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.
Jiashu ZhangDepartment of Neurosurgery, First Medical Center of Chinese PLA General Hospital, Beijing 100853, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mixed Reality Navigation (MRN) is pivotal in augmented reality-assisted intelligent neurosurgical interventions. However, existing MRN registration methods face challenges in concurrently achieving low user dependency, high accuracy, and clinical applicability. This study proposes and evaluates a novel registration method based on a laser crosshair simulator, evaluating its feasibility and accuracy. A novel registration method employing a laser crosshair simulator was introduced, designed to replicate the scanner frame's position on the patient. The system autonomously calculates the transformation, mapping coordinates from the tracking space to the reference image space. A mathematical model and workflow for registration were designed, and a Universal Windows Platform (UWP) application was developed on HoloLens-2. Finally, a head phantom was used to measure the system's target registration error (TRE). The proposed method was successfully implemented, obviating the need for user interactions with virtual objects during the registration process. Regarding accuracy, the average deviation was 3.7 ± 1.7 mm. This method shows encouraging results in efficiency and intuitiveness and marks a valuable advancement in low-cost, easy-to-use MRN systems. The potential for enhancing accuracy and adaptability in intervention procedures positions this approach as promising for improving surgical outcomes.

Indexed as

accuracyaugmented realitycrosshair simulatorhead phantomlasermixed reality navigationneurosurgical interventionspreoperative planningregistration methodtarget registration error

Identifiers

PMID38002414
PMCPMC10669875

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.