Evidence map›Paper›PMID 38002412›Full record

ArticleBioengineering (Basel, Switzerland)2023

Detection of Image Artifacts Using Improved Cascade Region-Based CNN for Quality Assessment of Endoscopic Images.

Wei Sun, Peng Li, Yan Liang, Yadong Feng, Lingxiao Zhao

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei SunSchool of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China.ORCID 0000-0002-4264-6622
Peng LiSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.ORCID 0000-0002-8001-0828
Yan LiangDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009, China.
Yadong FengDepartment of Gastroenterology, Zhongda Hospital, School of Medicine, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009, China.ORCID 0000-0001-9259-3840
Lingxiao ZhaoSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.

Funding

Jiangsu Provincal Special Program of Medical Science BE2019710
6 · The paper itself

Abstract

Endoscopy is a commonly used clinical method for gastrointestinal disorders. However, the complexity of the gastrointestinal environment can lead to artifacts. Consequently, the artifacts affect the visual perception of images captured during endoscopic examinations. Existing methods to assess image quality with no reference display limitations: some are artifact-specific, while others are poorly interpretable. This study presents an improved cascade region-based convolutional neural network (CNN) for detecting gastrointestinal artifacts to quantitatively assess the quality of endoscopic images. This method detects eight artifacts in endoscopic images and provides their localization, classification, and confidence scores; these scores represent image quality assessment results. The artifact detection component of this method enhances the feature pyramid structure, incorporates the channel attention mechanism into the feature extraction process, and combines shallow and deep features to improve the utilization of spatial information. The detection results are further used for image quality assessment. Experimental results using white light imaging, narrow-band imaging, and iodine-stained images demonstrate that the proposed artifact detection method achieved the highest average precision (62.4% at a 50% IOU threshold). Compared to the typical networks, the accuracy of this algorithm is improved. Furthermore, three clinicians validated that the proposed image quality assessment method based on the object detection of endoscopy artifacts achieves a correlation coefficient of 60.71%.

Indexed as

convolutional neural networkendoscopic image quality assessmentendoscopy artifacts

Identifiers

PMID38002412
PMCPMC10669857

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked