Evidence map›Paper›PMID 37999903›Full record

ArticlePhysical and engineering sciences in medicine2024

CAT-Seg: cascaded medical assistive tool integrating residual attention mechanisms and Squeeze-Net for 3D MRI biventricular segmentation.

Doaa A Shoieb, Karma M Fathalla, Sherin M Youssef, Ahmed Younes

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Doaa A ShoiebComputer Engineering Department, Arab Academy for Science, Technology and Maritime Transport (AASTMT), Alexandria, 1029, Egypt. doaa.shoieb@aast.edu.ORCID http://orcid.org/0000-0001-8054-0119
Karma M FathallaComputer Engineering Department, Arab Academy for Science, Technology and Maritime Transport (AASTMT), Alexandria, 1029, Egypt.
Sherin M YoussefComputer Engineering Department, Arab Academy for Science, Technology and Maritime Transport (AASTMT), Alexandria, 1029, Egypt.
Ahmed YounesDepartment of Mathematics and Computer Science, Faculty of Science, Alexandria University, Alexandria, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac image segmentation is a critical step in the early detection of cardiovascular disease. The segmentation of the biventricular is a prerequisite for evaluating cardiac function in cardiac magnetic resonance imaging (CMRI). In this paper, a cascaded model CAT-Seg is proposed for segmentation of 3D-CMRI volumes. CAT-Seg addresses the problem of biventricular confusion with other regions and localized the region of interest (ROI) to reduce the scope of processing. A modified DeepLabv3+ variant integrating SqueezeNet (SqueezeDeepLabv3+) is proposed as a part of CAT-Seg. SqueezeDeepLabv3+ handles the different shapes of the biventricular through the different cardiac phases, as the biventricular only accounts for small portion of the volume slices. Also, CAT-Seg presents a segmentation approach that integrates attention mechanisms into 3D Residual UNet architecture (3D-ResUNet) called 3D-ARU to improve the segmentation results of the three major structures (left ventricle (LV), Myocardium (Myo), and right ventricle (RV)). The integration of the spatial attention mechanism into ResUNet handles the fuzzy edges of the three structures. The proposed model achieves promising results in training and testing with the Automatic Cardiac Diagnosis Challenge (ACDC 2017) dataset and the external validation using MyoPs. CAT-Seg demonstrates competitive performance with state-of-the-art models. On ACDC 2017, CAT-Seg is able to segment LV, Myo, and RV with an average minimum dice symmetry coefficient (DSC) performance gap of 1.165%, 4.36%, and 3.115% respectively. The average maximum improvement in terms of DSC in segmenting LV, Myo and RV is 4.395%, 6.84% and 7.315% respectively. On MyoPs external validation, CAT-Seg outperformed the state-of-the-art in segmenting LV, Myo, and RV with an average minimum performance gap of 6.13%, 5.44%, and 2.912% respectively.

Indexed as

Accidental InjuriesImage Processing, Computer-AssistedConfusionHeartHeart VentriclesHumansMagnetic Resonance ImagingMyocardiumACDC datasetCardiovascularLeft ventricle (LV)Myocardium (Myo)Right ventricle (RV)

Identifiers

PMID37999903
PMCPMC10963474

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.