Evidence map›Paper›PMID 37999786›Full record

Trial reportJournal of anesthesia2024

Usefulness of an automatic cuff pressure controller (SmartCuff) in inhibiting gasleakage around the cuff after tracheal intubation: a randomized controlled study.

Kazuhiro Urabe, Takashi Asai, Yasuhisa Okuda

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Journal of anesthesia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kazuhiro UrabeDepartment of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan.
Takashi AsaiDepartment of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan. asaita@dokkyomed.ac.jp.ORCID 0000-0001-9202-9932
Yasuhisa OkudaDepartment of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50, Minami-Koshigaya, Koshigaya, Saitama, 343-8555, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeGas leakage around the cuff of a tracheal tube may frequently occur after tracheal intubation and inflation of the cuff. We assessed if the SmartCuff (Smiths Medical Japan, Tokyo, Japan), an automatic cuff pressure controller, would effectively prevent gas leakage.

methodsSeventy adult patients were allocated randomly to one of two groups. After induction of general anesthesia and tracheal intubation, in one group (Syringe group), a syringe was used to inflate the cuff, until there was no audible gas leakage, at the airway pressure at 20 cmH

resultsThe incidence of audible gas leakage was significantly higher in the Syringe group (10 of 35 patients (28%)) than in the SmartCuff group (none of 35 patients (0%)) (P = 0.00046, 95%CI for difference: 15-43%), and the proportion of adequate seal was significantly lower in the Syringe group (19 of 35 patients (54%)) than in the Smart cuff group (33 of 35 patients (94%)) (P = 0.0001, 95% CI for difference: 20-58%).

conclusionGas leakage may frequently occur after tracheal intubation, and the use of the SmartCuff can effectively maintain the sealing effect of the cuff.

Indexed as

Intubation, IntratrachealRespiration, ArtificialAdultAnesthesia, GeneralHumansPressureTidal VolumeAirway managementCuff pressure monitorIntracuff pressureTracheal intubation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked