Evidence map›Paper›PMID 37998951›Full record

ArticleGels (Basel, Switzerland)2023

Application of Silica-Aerogel-Fibre-Based Thermal Renders for Retrofits in Building Walls: A Comparative Assessment with Benchmark Solutions.

Marco Pedroso, José Dinis Silvestre, M Glória Gomes, Jéssica D Bersch, Inês Flores-Colen

Abstract read
In one paragraph

Article in Gels (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marco PedrosoCivil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.ORCID 0000-0002-8119-6847
José Dinis SilvestreCivil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.ORCID 0000-0002-3330-2000
M Glória GomesCivil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.ORCID 0000-0003-1499-1370
Jéssica D BerschCivil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.ORCID 0000-0001-9287-6170
Inês Flores-ColenCivil Engineering Research and Innovation for Sustainability (CERIS), Departamento de Engenharia Civil, Arquitetura e Ambiente (DECivil), Instituto Superior Técnico (IST), Universidade de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal.ORCID 0000-0003-4038-6748

Funding

FCT - Foundation for Science and Technology SFRH/BD/132239/2017
6 · The paper itself

Abstract

The current climate change context raises the demand for reducing energy and environmental impacts while keeping an economic balance and building users' comfort. Thermal insulation solutions are potential allies in ensuring the adequacy of existing buildings for challenging sustainability requirements. In this scenario, silica-aerogel-fibre-based thermal renders are innovative solutions for which integrated approaches still lack information, and they should be compared with benchmark multilayer solutions, such as those based on expanded polystyrene (EPS), extruded polystyrene (XPS), mineral wool (MW), and insulated corkboard (ICB), to evidence their prospective economic, environmental, and energy benefits. This paper quantifies the optimum insulation thicknesses, life cycle savings, payback periods, and environmental impacts of innovative thermal renders compared to conventional thermal insulation materials when applied as a retrofit in existing facade walls. The results show that cost-optimised thermal renders with sisal fibres led to the best overall performance. Higher heating needs led to higher optimum render thicknesses and life cycle savings. With a 0.02 m thickness, aerogel-fibre-based thermal renders outperformed other materials in terms of heating-degree days (HDD) from 1000 °C·day onwards; they can save approximately EUR 60∙m

Indexed as

environmental impactsfacadefibrelife cycle savingsoptimum insulation thicknesspayback periodsretrofitsilica aerogelthermal insulationthermal render

Identifiers

PMID37998951
PMCPMC10670856

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.