Evidence map›Paper›PMID 37997605›Full record

ArticleIEEE robotics and automation letters2023

Real-time intraoperative surgical guidance system in the da Vinci surgical robot based on transrectal ultrasound/photoacoustic imaging with photoacoustic markers: an

Hyunwoo Song, Hamid Moradi, Baichuan Jiang, Keshuai Xu, Yixuan Wu, Russell H Taylor, Anton Deguet, Jin U Kang, Septimiu E Salcudean, Emad M Boctor

Abstract read
In one paragraph

Article in IEEE robotics and automation letters, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Photoacoustic imaging plus X: a review.Journal of biomedical optics · 2024
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hyunwoo SongDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Hamid MoradiDepartment of Electrical and Computer Engineering, the University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Baichuan JiangDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Keshuai XuDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Yixuan WuDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Russell H TaylorDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Anton DeguetDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.
Jin U KangDepartment of Electrical and Computer Engineering, Whiting school of Engineering, the Johns Hopkins University, Baltimore, MD 21211 USA.
Septimiu E SalcudeanDepartment of Electrical and Computer Engineering, the University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Emad M BoctorDepartment of Computer Science, Whiting School of Engineering, the Johns Hopkins University, Baltimore, MD 21218 USA.

Funding

PSMA-based Cancer Imaging AgentsR01CA134675 · NCI · UT SOUTHWESTERN MEDICAL CENTER · PI POMPER, MARTIN G · 2009 to 2025
$6.2M
NCI NIH HHS R01 CA134675
6 · The paper itself

Abstract

This paper introduces the first integrated real-time intraoperative surgical guidance system, in which an endoscope camera of da Vinci surgical robot and a transrectal ultrasound (TRUS) transducer are co-registered using photoacoustic markers that are detected in both fluorescence (FL) and photoacoustic (PA) imaging. The co-registered system enables the TRUS transducer to track the laser spot illuminated by a pulsed-laser-diode attached to the surgical instrument, providing both FL and PA images of the surgical region-of-interest (ROI). As a result, the generated photoacoustic marker is visualized and localized in the da Vinci endoscopic FL images, and the corresponding tracking can be conducted by rotating the TRUS transducer to display the PA image of the marker. A quantitative evaluation revealed that the average registration and tracking errors were 0.84 mm and 1.16°, respectively. This study shows that the co-registered photoacoustic marker tracking can be effectively deployed intraoperatively using TRUS+PA imaging providing functional guidance of the surgical ROI.

Indexed as

medical robots and systemsphotoacoustic imagingsoftware-hardware integration for robot systemssurgical guidance systemtransrectal ultrasound imaging

Identifiers

PMID37997605
PMCPMC10664816

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.