Evidence map›Paper›PMID 37996124›Full record

ArticleRMD open2023

A stretchable hardness sensor for the assessment of skin disease in systemic sclerosis.

Xiuyuan Wang, Mengyang Liu, Tianbao Ye, Junxia Huang, Xinzhi Xu, Ming Li, Xuefeng Zhao, Hongliang Lu, Ji Yang

Open access · goldAbstract read
In one paragraph

Article in RMD open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Xiuyuan Wang *Department of Dermatology, Zhongshan Hospital Fudan University, Shanghai, China.ORCID 0000-0002-7996-6929
Mengyang Liu *Fudan University, Shanghai, China.
Tianbao Ye *Shanghai Sixth People's Hospital, Shanghai, China.
Junxia HuangDepartment of Dermatology, Zhongshan Hospital Fudan University, Shanghai, China.
Xinzhi XuDepartment of Dermatology, Zhongshan Hospital Fudan University, Shanghai, China.
Ming LiDepartment of Dermatology, Zhongshan Hospital Fudan University, Shanghai, China.
Xuefeng ZhaoFudan University, Shanghai, China.
Hongliang LuFudan University, Shanghai, China.
Ji YangDepartment of Dermatology, Zhongshan Hospital Fudan University, Shanghai, China yang.hua@yeah.net.
Sun Yat-sen University · CNFudan University · CNShanghai Sixth People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo determine the validity of a hardness sensor to objectively assess skin induration in patients with systemic sclerosis, and to compare the hardness sensor with the modified Rodnan skin score (MRSS) and a durometer.

methodsThe skin induration was measured in two assessments: a Latin square experiment to examine the hardness sensor's intraobserver and interobserver reliability; and a longitudinal cohort to evaluate the distribution of hardness sensor measurements, the correlation between hardness sensor, durometer and MRSS, and the sensitivity to change in skin hardness. Other outcome data collected included the health assessment questionnaire (HAQ) disability index and Keitel function test (KTF) score.

resultsThe reliability of the hardness sensor was excellent, with high intraobserver and interobserver intraclass correlation coefficients (0.97; 0.96), which was higher than MRSS (0.86; 0.74). Interobserver reproducibility of hardness sensor was only poor in abdomen (0.38), yet for durometer it was poor in face (0.11) and abdomen (0.33). The hardness sensor score provided a greater dynamic evaluation range than MRSS. Total hardness sensor score correlated well with MRSS (r=0.90, p<0.001), total durometer score (r=0.95, p<0.001), HAQ disability index (r=0.70, p<0.001) and KTF score (r=0.66, p<0.001). Change in hardness sensor score also correlated with change in MRSS (r=0.78, p<0.001), total durometer score (r=0.85, p<0.001), HAQ disability index (r=0.76, p<0.001) and KTF score (r=0.67, p<0.001).

conclusionThe hardness sensor showed greater reproducibility and accuracy than MRSS, and more application sites than durometer; it can also reflect patients' self-assessments and function test outcomes.

Indexed as

Scleroderma, SystemicSkin DiseasesHardnessHumansReproducibility of ResultsSkinOutcome and Process Assessment, Health CareScleroderma, SystemicSystemic Sclerosis

Identifiers

PMID37996124
PMCPMC10668276
OpenAlexW4388947815

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.