Repeatability and agreement of AOCT-1000 M, RTVue XR and IOL master 500 in measuring corneal thickness mapping and axial length applying principle of optical coherence tomography.

Hailong Ni, Suzhong Xu, Li Tian, Jieli Mao, Jing Li, Na Lin, Peike Hu, Zhiyi Wu, Xiang Chen, Zhishu Bao and 3 more

Abstract read
In one paragraph

Article in BMC medical imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Genome-Wide Association Analysis Identifies LILRB2 Gene for Pathological Myopia.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Hailong Ni *Eye Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310010, China.
Suzhong Xu *Eye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Li TianEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Jieli MaoEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Jing LiEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Na LinEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Peike HuEye Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310010, China.
Zhiyi WuEye Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310010, China.
Xiang ChenEye Center, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310010, China.
Zhishu BaoEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Jingwei ZhengEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China.
Peihua YanVision X Medical Technology Co., Ltd., Shanghai, 201112, China.
Ruzhi DengEye hospital of Wenzhou Medical University, Wenzhou, Zhejiang, 32500, China. drz@eye.ac.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the repeatability and agreement of Fourier-domain optical coherence tomography (AOCT-1000 M and RTVue XR) and partial coherence interferometry biometer (IOL Master 500) in measuring corneal thickness mapping and axial length respectively.

methodsCorneal thickness was measured by AOCT-1000 M and RTVue XR. Axial lengths were measured by AOCT-1000 M and IOL Master 500. The repeatability and agreement of corneal thickness and axial length were calculated in two groups of devices. The intraclass correlation coefficient (ICC) was used to verify the repeatability of the device. The 95% confidence interval of the difference compared to the set cut-off value was used to verify the agreement between the two devices.

resultsA total of 60 subjects with 58 eyes were included. The central corneal thickness measured by AOCT-1000 M and RTVue XR were 504.46 ± 42.53 μm and 504.43 ± 42.89 μm respectively. The average difference between groups was 0.03 ± 4.58 μm, and the 95% confidence interval was (-1.17, 1.24), which was far less than the set threshold value of 15 μm (P < 0.001). Both RTVue XR and AOCT-1000 M had very good ICC values of central corneal thickness (0.998 and 0.994, respectively). The average axial lengths measured by AOCT-1000 M and IOL Master 500 were 24.28 ± 1.25 mm and 24.29 ± 1.26 mm respectively and the 95% confidence interval was (-0.02, 0.01), which was less than the set threshold value of 0.15 mm (P < 0.001). The ICC for both devices were 1.000.

conclusionGood repeatability and agreement were seen in measurements of central corneal thickness and axial length by AOCT-1000 M.

Indexed as

CorneaTomography, Optical CoherenceHumansReproducibility of ResultsAgreementAOCT-1000 MAxial lengthCentral corneal thicknessRepeatabilityRTVue XR

Identifiers

PMID37990166
PMCPMC10664477

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.