Evidence map›Paper›PMID 37989990›Full record

ArticleMedical & biological engineering & computing2024

In silico study about the influence of electroporation parameters on the cellular internalization, spatial uniformity, and cytotoxic effects of chemotherapeutic drugs using the Method of Fundamental Solutions.

Fabián Mauricio Vélez Salazar, Iván David Patiño Arcila

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Fabián Mauricio Vélez Salazar *Grupo de Investigación E Innovación Ambiental (GIIAM), Institución Universitaria Pascual Bravo, Cl. 73 No 73A-226 (Bloque 7), Medellín, Colombia.
Iván David Patiño Arcila *Grupo de Investigación E Innovación Ambiental (GIIAM), Institución Universitaria Pascual Bravo, Cl. 73 No 73A-226 (Bloque 7), Medellín, Colombia. i.patinoar@pascualbravo.edu.co.
Instituto Tecnológico Metropolitano · COPascual Bravo Institution University · CO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Reversible electroporation is a suitable technique to aid the internalization of medicaments in cancer tissues without inducing permanent cellular damage, allowing the enhancement of cytotoxic effects without incurring in electric-driven necrotic or apoptotic processes by the presence of non-reversible aqueous pores. An adequate selection of electroporation parameters acquires relevance to reach these goals and avoid opposite effects. This work applies the Method of Fundamental Solutions (MFS) for drug transport simulations in electroporated cancer tissues, using a continuum tumor cord approach and considering both electro-permeabilization and vasoconstriction effects. The MFS algorithm is validated with published results, obtaining satisfactory accuracy and convergence. Then, MFS simulations are executed to study the influence of electric field magnitude [Formula: see text], number of electroporation treatments [Formula: see text], and electroporation time [Formula: see text] on three assessment parameters of electrochemotherapy: the internationalization efficacy accounting for the ability of the therapy to introduce moles into viable cells, cell-kill capacity indicating the faculty to reduce the survival fraction of cancer cells, and distribution uniformity specifying the competence to supply drug homogeneously through the whole tissue domain. According to numerical results, when [Formula: see text] is the reversibility threshold, a positive influence on the first two parameters is only possible once specific values of [Formula: see text] and [Formula: see text] have been exceeded; when [Formula: see text] is just the irreversibility threshold, any combination of [Formula: see text] and [Formula: see text] is beneficial. On the other hand, the drug distribution uniformity is always adversely affected by the application of electric pulses, being this more noticeable as [Formula: see text], [Formula: see text], and [Formula: see text] increases.

Indexed as

ElectroporationNeoplasmsAlgorithmsApoptosisElectricityHumansAnticancer drug internalizationCell survival rateElectrochemotherapyMethod of Fundamental SolutionsTreatment efficacy

Identifiers

PMID37989990
OpenAlexW4388880083

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked