Evidence map›Paper›PMID 37989847›Full record

ReviewAnalytical and bioanalytical chemistry2024

Advances in electrochemical biosensor design for the detection of the stress biomarker cortisol.

Courtney J Weber, Olivia M Clay, Reese E Lycan, Gracie K Anderson, Olja Simoska

Abstract readReview
PubMed Publisher
In one paragraph

Review in Analytical and bioanalytical chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
7.1field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Courtney J WeberDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA.
Olivia M ClayDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA.
Reese E LycanDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA.
Gracie K AndersonDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA.
Olja SimoskaDepartment of Chemistry and Biochemistry, University of South Carolina, Columbia, SC, 29208, USA. osimoska@mailbox.sc.edu.ORCID http://orcid.org/0000-0001-5356-721X
University of South Carolina · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The monitoring of stress levels in humans has become increasingly relevant, given the recent incline of stress-related mental health disorders, lifestyle impacts, and chronic physiological diseases. Long-term exposure to stress can induce anxiety and depression, heart disease, and risky behaviors, such as drug and alcohol abuse. Biomarker molecules can be quantified in biological fluids to study human stress. Cortisol, specifically, is a hormone biomarker produced in the adrenal glands with biofluid concentrations that directly correlate to stress levels in humans. The rapid, real-time detection of cortisol is necessary for stress management and predicting the onset of psychological and physical ailments. Current methods, including mass spectrometry and immunoassays, are effective for sensitive cortisol quantification. However, these techniques provide only single measurements which pose challenges in the continuous monitoring of stress levels. Additionally, these analytical methods often require trained personnel to operate expensive instrumentation. Alternatively, low-cost electrochemical biosensors enable the real-time detection and continuous monitoring of cortisol levels while also providing adequate analytical figures of merit (e.g., sensitivity, selectivity, sensor response times, detection limits, and reproducibility) in a simple design platform. This review discusses the recent developments in electrochemical biosensor design for the detection of cortisol in human biofluids. Special emphasis is given to biosensor recognition elements, including antibodies, molecularly imprinted polymers (MIPs), and aptamers, as critical components of electrochemical biosensors for cortisol detection. Furthermore, the advantages and limiting factors of various electrochemical techniques and sensing in complex biofluid matrices are overviewed. Remarks on the current challenges and future perspectives regarding electrochemical biosensors for stress monitoring are provided, including matrix effects (pH dependence and biological interferences), wearability, and large-scale production.

Indexed as

Biosensing TechniquesHydrocortisoneAntibodiesBiomarkersElectrochemical TechniquesHumansReproducibility of ResultsAntibodiesBiomarkersHydrocortisoneBiofluidsElectrochemical biosensorsElectrode materialsRecognition elementsStress biomarkers

Identifiers

PMID37989847
OpenAlexW4388879949

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.