Evidence map›Paper›PMID 37989763›Full record

ArticleUnfallchirurgie (Heidelberg, Germany)2024

[Precision and safety of positioning pedicle screws in the thoracic and lumbar spine using a hand-guided aiming sleeve : A CT control study].

Silke Vißmann, Philippus Schöttes, Fatma Topcuoglu, Thorsten Strohmann, Jens-Peter Stahl, Stefan Rohde

Abstract readEnglish Abstract
PubMed Publisher
In one paragraph

Article in Unfallchirurgie (Heidelberg, Germany), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 65% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Silke VißmannKlinik für Radiologie und Neuroradiologie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Dortmund, Deutschland. silke.vissmann@hotmail.de.ORCID http://orcid.org/0009-0004-0821-8415
Philippus SchöttesKlinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Münsterstraße 240, 44137, Dortmund, Deutschland.
Fatma TopcuogluKlinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Münsterstraße 240, 44137, Dortmund, Deutschland.
Thorsten StrohmannKlinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Münsterstraße 240, 44137, Dortmund, Deutschland.
Jens-Peter StahlKlinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Münsterstraße 240, 44137, Dortmund, Deutschland.
Stefan RohdeKlinik für Radiologie und Neuroradiologie, Klinikum Dortmund gGmbH, Klinikum der Universität Witten/Herdecke, Dortmund, Deutschland.
Witten/Herdecke University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFor the implantation of pedicle screws, navigation-supported systems are nowadays used more and more to avoid screw misalignment by making the direction of the screw more predictable.

objectiveExamination of the precision after instrumentation of the pedicle screw with the hand-guided aiming sleeve. The aim was to verify that the implementation of the pedicle screws is plannable and precise by using 2D X‑ray only.

methodThis retrospective study analyzed 27 consecutive trauma patients (17-84 years, 13f/14m) with vertebral body fractures. The position and precision of 108 screws, implanted using the hand-guided aiming sleeve was investigated. To determine the position the actual course of the screws was examined using the postoperative 3D CT data set (GE Optima 540, General Electric Company Boston, MA, USA; slice thickness 1.25 mm). The screws were then compared to the previously defined ideal position of the tip of the screw. In addition to the absolute and relative deviation from the ideal target point, the convergence angle and the parallelism to the cover plate were determined.

resultsOf 108 implanted pedicle screws, 90 (83%) were within target. The remaining 18 (17%) represented a clinically irrelevant screw deviation: A lateral deviation was found in 17 pedicle screws (16%) and a medial deviation in 1 (1%). The average deviation from the ideal target point in the vertebral body was 2.3 mm ventrally with a standard deviation of ± 2.3 mm. No screw misalignment or pedicle perforation was found.

conclusionThe transcutaneous implantation of pedicle screws with a hand-guided aiming sleeve in the thoracic and lumbar spine represents a safe and precise procedure. The risk of misalignment needing a revision is lower compared to other methods of navigated screw implantation reported in the literature [1-6]. A CT-based preliminary planning is not necessary. The method is economical, special technical equipment is not required.

Indexed as

Pedicle ScrewsSpinal FracturesSpinal FusionHumansLumbar VertebraeRetrospective StudiesTomography, X-Ray ComputedFreehand methodNavigationScrew misalignmentSpinal surgeryVertebral body fractures

Identifiers

PMID37989763
OpenAlexW4388857052

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.