ArticleClinical biomechanics (Bristol, Avon)2024

Functionally graded 3D printed plates for rib fracture fixation.

Richa Gupta, Lauren Judkins, Chet S Friday, Joseph B Ulsh, Stephen J Kovach, Samir Mehta, Charles Tomonto, Guha Manogharan, Michael W Hast

Abstract read
In one paragraph

Article in Clinical biomechanics (Bristol, Avon), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Richa GuptaMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Lauren JudkinsDepartment of Mechanical Engineering, Pennsylvania State University, University Park, PA, USA.
Chet S FridayMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Joseph B UlshMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Stephen J KovachMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Samir MehtaMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Charles TomontoJohnson and Johnson Services, Inc., Miami, FL, USA.
Guha ManogharanDepartment of Mechanical Engineering, Pennsylvania State University, University Park, PA, USA.
Michael W HastMcKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: hast@pennmedicine.upenn.edu.

Funding

Overall: Resource-based Center for Musculoskeletal Disorders Research (Overall Application)P30AR069619 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI LOUIS J SOSLOWSKY · 2016 to 2026
$9.1M
NIAMS NIH HHS P30 AR069619
6 · The paper itself

Abstract

backgroundDesign freedom offered by additive manufacturing allows for the implementation of functional gradients - where mechanical stiffness is decreased along the length of the implant. It is unclear if such changes will influence failure mechanisms in the context of rib fracture repair. We hypothesized that our novel functionally graded rib implants would be less stiff than controls and decrease occurrence of secondary fracture at implant ends.

methodsFive novel additively manufactured rib implants were tested along with a clinically used Control implant. Fracture reconstructions were modeled with custom synthetic rib bones with a transverse B1 fracture. Ribs were compressed in a cyclic two-point bend test for 360,000 cycles followed by a ramp to failure test. Differences in cyclic stiffness, 3D interfragmentary motions, ramp-to-failure stiffness, maximum load, and work to failure were determined.

findingsThe Control group had lower construct stiffness (0.76 ± 0.28 N/mm), compared to all novel implant designs (means: 1.35-1.61 N/mm, p < 0.05) and rotated significantly more about the bending axis (2.7° ± 1.3°) than the additively manufactured groups (means between 1.2° - 1.6°, p < 0.05). All constructs failed via bone fracture at the most posterior screw hole. Experimental implants were stiffer than Controls, and there were few significant differences between functional gradient groups.

interpretationAdditively manufactured, functionally graded designs have the potential to change the form and function of trauma implants. Here, the impact of functional gradients was limited because implants had small cross-sectional areas.

Indexed as

Rib FracturesBiomechanical PhenomenaBone PlatesBone ScrewsFracture FixationFracture Fixation, InternalHumansPrinting, Three-DimensionalRibsAdditive manufacturingBiomechanicsFracture fixationRib fracture

Identifiers

PMID37989063
PMCPMC10842059

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.