ArticleJMIR mHealth and uHealth2023
Exploring Variations in Sleep Perception: Comparative Study of Chatbot Sleep Logs and Fitbit Sleep Data.
Article in JMIR mHealth and uHealth, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Human-Centered AI in Sleep Health Management: Scoping Review of Stakeholder Perspectives and Co-Design Practices.Journal of medical Internet research · 2026Article
- A Scoping Review of Large Language Models in Personal Sleep Wellness.Mayo Clinic proceedings. Digital health · 2025Review
- Sleep misperception and associated factors among middle-aged women in Korea: a cross-sectional study.Journal of Korean biological nursing science · 2025Article
- Pilot study comparing sleep logs to a commercial wearable device in describing the sleep patterns of physicians-in-training.PloS one · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPatient-generated health data are important in the management of several diseases. Although there are limitations, information can be obtained using a wearable device and time-related information such as exercise time or sleep time can also be obtained. Fitbits can be used to acquire sleep onset, sleep offset, total sleep time (TST), and wakefulness after sleep onset (WASO) data, although there are limitations regarding the depth of sleep and satisfaction; therefore, the patient's subjective response is still important information that cannot be replaced by wearable devices.
objectiveTo effectively use patient-generated health data related to time such as sleep, it is first necessary to understand the characteristics of the time response recorded by the user. Therefore, the aim of this study was to analyze the characteristics of individuals' time perception in comparison with wearable data.
methodsSleep data were acquired for 2 weeks using a Fitbit. Participants' sleep records were collected daily through chatbot conversations while wearing the Fitbit, and the two sets of data were statistically compared.
resultsIn total, 736 people aged 30-59 years were recruited for this study, and the sleep data of 543 people who wore a Fitbit and responded to the chatbot for more than 7 days on the same day were analyzed. Research participants tended to respond to sleep-related times on the hour or in 30-minute increments, and each participant responded within the range of 60-90 minutes from the value measured by the Fitbit. On average for all participants, the chat responses and the Fitbit data were similar within a difference of approximately 15 minutes. Regarding sleep onset, the participant response was 8 minutes and 39 seconds (SD 58 minutes) later than that of the Fitbit data, whereas with respect to sleep offset, the response was 5 minutes and 38 seconds (SD 57 minutes) earlier. The participants' actual sleep time (AST) indicated in the chat was similar to that obtained by subtracting the WASO from the TST measured by the Fitbit. The AST was 13 minutes and 39 seconds (SD 87 minutes) longer than the time WASO was subtracted from the Fitbit TST. On days when the participants reported good sleep, they responded 19 (SD 90) minutes longer on the AST than the Fitbit data. However, for each sleep event, the probability that the participant's AST was within ±30 and ±60 minutes of the Fitbit TST-WASO was 50.7% and 74.3%, respectively.
conclusionsThe chatbot sleep response and Fitbit measured time were similar on average and the study participants had a slight tendency to perceive a relatively long sleep time if the quality of sleep was self-reported as good. However, on a participant-by-participant basis, it was difficult to predict participants' sleep duration responses with Fitbit data. Individual variations in sleep time perception significantly affect patient responses related to sleep, revealing the limitations of objective measures obtained through wearable devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.