ArticleCardiovascular engineering and technology2023
Novel Peripheral Perfusion Dynamics Indices for Detecting and Grading Arterial Stenosis.
Article in Cardiovascular engineering and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Pressure-Pressure Loop: A Novel Method for Biophysical Characterization of Blood Vessels.Annals of biomedical engineering · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
purposePeripheral artery disease causes severe morbidity, especially in diabetics and the elderly. There is a need for accurate noninvasive detection of peripheral arterial stenosis. The study has tested the hypothesis that arterial stenosis and the associated adaptation of the downstream circulation yield characteristic changes in the leg perfusion dynamics that enable early diagnosis, utilizing impedance plethysmography.
methodsThe arterial perfusion dynamic was derived from impedance plethysmography (IPG). Two degrees of arterial stenosis were emulated by inflating a blood-pressure cuff around the thigh to 45 and 90 mmHg, in healthy volunteers (n = 30). IPG signals were acquired continuously throughout the experiment. Ankle and brachial blood pressures were measured at the beginning of each experiment and at the end of each emulated stenosis phase.
resultsThigh compressions did not affect the pulse-transit time, but prolonged the time to the peak perfusion wave. Segmentation of the perfusion upstroke into two phases, at the time point of maximum acceleration (MAT), revealed that arterial compression prolonged only the initial slow phase duration (SPd). The MAT and SPd were proportional to the emulated stenosis severity and detected the arterial stenosis with high sensitivity (> 93%) and specificity (100%). The SPd increased from 46.4 ± 21.2 ms at baseline to 75.4 ± 38.5 ms and 145 ± 39 ms under 45 mmHg and 90 mmHg compressions (p < 0.001), without affecting the pulse-transit time.