ArticleBMJ open quality2023
Improving the longevity of intravenous cannulas in sick neonates admitted to NICU in a tertiary care centre: a quality improvement project.
Article in BMJ open quality, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNeonatal intravenous cannulation, especially in preterms, is more challenging than in children or adults. Placement of an intravenous cannula is painful and many cannulas need frequent changing due to complications. Each attempt at cannulation creates an entry for skin flora to cause systemic bacteraemia. This study was undertaken at a level III NICU. The team attempted to prolong the existing cannula longevity to reduce the frequency of intravenous cannulation thereby reducing handling and pain.
objectivesTo improve the longevity of peripherally inserted intravenous cannula in sick neonates in NICU from the current 25.7 hours to 36 hours or more, over a span of 6 weeks. MATERIALS AND
methodsThe quality improvement (QI) team comprised resident doctors and staff nurses. A fishbone analysis was used to identify factors that affected the longevity of intravenous cannulas. Five WHYs technique was used to identify the cause behind early cannula removal. Both techniques identified the fixation technique used at the study centre for target intervention. Plan-Do-Study-Act cycles were planned to explore different fixation techniques to improve cannula longevity. The unpaired t-test and the χ
resultsWe achieved significant improvement in cannula longevity from 25.7 hours to 39.6 hours just by improving the fixation technique over 6 weeks with a p=0.0006.
conclusionsThe QI study was successful and is adopted for routine practice. Such initiatives would greatly impact babies in low-resource settings and in transit.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.