Evidence map›Paper›PMID 37982845›Full record

ArticleAnalytical and bioanalytical chemistry2023

The Good pH probe: non-invasive pH in-line monitoring using Good buffers and Raman spectroscopy.

David Heinrich Müller, Marieke Börger, Julia Thien, Hans-Jürgen Koß

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

David Heinrich MüllerInstitute of Technical Thermodynamics, RWTH Aachen University, Schinkelstraße 8, 52062, Aachen, Germany.ORCID http://orcid.org/0000-0002-4761-2640
Marieke BörgerInstitute of Technical Thermodynamics, RWTH Aachen University, Schinkelstraße 8, 52062, Aachen, Germany.
Julia ThienInstitute of Technical Thermodynamics, RWTH Aachen University, Schinkelstraße 8, 52062, Aachen, Germany.ORCID http://orcid.org/0000-0001-7440-6407
Hans-Jürgen KoßInstitute of Technical Thermodynamics, RWTH Aachen University, Schinkelstraße 8, 52062, Aachen, Germany. hans-juergen.koss@ltt.rwth-aachen.de.ORCID http://orcid.org/0000-0002-0665-8781

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In bioprocesses, the pH value is a critical process parameter that requires monitoring and control. For pH monitoring, potentiometric methods such as pH electrodes are state of the art. However, they are invasive and show measurement value drift. Spectroscopic pH monitoring is a non-invasive alternative to potentiometric methods avoiding this measurement value drift. In this study, we developed the Good pH probe, which is an approach for spectroscopic pH monitoring in bioprocesses with an effective working range between pH 6 and pH 8 that does not require the estimation of activity coefficients. The Good pH probe combines for the first time the Good buffer 3-(N-morpholino)propanesulfonic acid (MOPS) as pH indicator with Raman spectroscopy as spectroscopic technique, and Indirect Hard Modeling (IHM) for the spectral evaluation. During a detailed characterization, we proved that the Good pH probe is reversible, exhibits no temperature dependence between 15 and 40 °C, has low sensitivity to the ionic strength up to 1100 mM, and is applicable in more complex systems, in which other components significantly superimpose the spectral features of MOPS. Finally, the Good pH probe was successfully used for non-invasive pH in-line monitoring during an industrially relevant enzyme-catalyzed reaction with a root mean square error of prediction (RMSEP) of 0.04 pH levels. Thus, the Good pH probe extends the list of critical process parameters monitorable using Raman spectroscopy and IHM by the pH value.

Indexed as

3-(N-Morpholino)propanesulfonic acid (MOPS)Good buffersIndirect Hard Modeling (IHM)In-line monitoringpH valueRaman spectroscopy

Identifiers

PMID37982845
PMCPMC10684429

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.