Evidence map›Paper›PMID 37981826›Full record

ArticleUltrasonic imaging2024

High-frequency Quantitative Ultrasound Imaging of Human Rotator Cuff Muscles: Assessment of Repeatability and Reproducibility.

Yuanshan Wu, Victor Barrere, Aria Ashir, Xiaojun Chen, Livia T Silva, Saeed Jerban, Aiguo Han, Michael P Andre, Sameer B Shah, Eric Y Chang

Open access · greenAbstract read
In one paragraph

Article in Ultrasonic imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Yuanshan WuDepartment of Bioengineering, University of California, San Diego, CA, USA.ORCID 0009-0008-5842-3969
Victor BarrereDepartment of Orthopaedic Surgery, University of California, San Diego, CA, USA.
Aria AshirDepartment of Radiology, Santa Barbara Cottage Hospital, Santa Barbara, CA, USA.
Xiaojun ChenDepartment of Radiology, University of California, San Diego, CA, USA.
Livia T SilvaDepartment of Radiology, University of California, San Diego, CA, USA.
Saeed JerbanResearch Service, VA San Diego Healthcare System, San Diego, CA, USA.
Aiguo HanDepartment of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA.ORCID 0000-0001-7606-9221
Michael P AndreResearch Service, VA San Diego Healthcare System, San Diego, CA, USA.
Sameer B ShahDepartment of Bioengineering, University of California, San Diego, CA, USA.
Eric Y ChangDepartment of Radiology, University of California, San Diego, CA, USA.
University of California San Diego · USSanta Barbara Cottage Hospital · USSun Yat-sen University · CNVirginia Tech · US

Funding

Three-dimensional Ultrashort Echo Time Magnetic Resonance Imaging of EnthesesR01AR075825 · NIAMS · VETERANS MEDICAL RESEARCH FDN/SAN DIEGO · PI CHANG, ERIC Y · 2019 to 2023
$1.8M
Knee evaluation under mechanical loading by cones ultrashort echo time MR imagingK01AR080257 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI saeed jerban · 2022 to 2026
$602k
Multi-scale MRI Assessment of Bone Quality and Function in a Chronic Rat Spinal Cord Injury ModelI01BX005952 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI Eric Y Chang · 2023 to 2026
–
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Medical Imaging of Peripheral Nerve Injury and RepairI01CX002118 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI Sameer B. Shah · 2021 to 2026
–
BLRD VA I01 BX005952CSRD VA I01 CX001388CSRD VA I01 CX002118NIAMS NIH HHS K01 AR080257NIAMS NIH HHS R01 AR075825
6 · The paper itself

Abstract

This study evaluated the repeatability and reproducibility of using high-frequency quantitative ultrasound (QUS) measurement of backscatter coefficient (BSC), grayscale analysis, and gray-level co-occurrence matrix (GLCM) textural analysis, to characterize human rotator cuff muscles. The effects of varying scanner settings across two different operators and two US systems were investigated in a healthy volunteer with normal rotator cuff muscles and a patient with chronic massive rotator cuff injury and substantial muscle degeneration. The results suggest that BSC is a promising method for assessing rotator cuff muscles in both control and pathological subjects, even when operators were free to adjust system settings (depth, level of focus, and time-gain compensation). Measurements were repeatable and reproducible across the different operators and ultrasound imaging platforms. In contrast, grayscale and GLCM analyses were found to be less reliable in this setting, with significant measurement variability. Overall, the repeatability and reproducibility measurements of BSC indicate its potential as a diagnostic tool for rotator cuff muscle evaluation.

Indexed as

Adipose TissueRotator CuffHumansMagnetic Resonance ImagingReproducibility of ResultsUltrasonographybackscatter coefficienthigh frequency imagingquantitative imaging biomarkers alliancequantitative ultrasoundrotator cuff musclestextural characterization

Identifiers

PMID37981826
PMCPMC11170563
OpenAlexW4388830268

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.