Evidence map›Paper›PMID 37980432›Full record

ArticleScientific reports2023

Quantitative evaluation of rat sciatic nerve degeneration using high-frequency ultrasound.

Yuanshan Wu, Victor Barrere, Aiguo Han, Michael P Andre, Elisabeth Orozco, Xin Cheng, Eric Y Chang, Sameer B Shah

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Influences of Variability in Attenuation Compensation on the Estimation of Backscatter Coefficient of Median Nerves in Vivo.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yuanshan WuDepartment of Bioengineering, University of California, San Diego, 9500 Gilman Drive, MC 0863, La Jolla, CA, 92093-0683, USA.
Victor BarrereDepartment of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA.
Aiguo HanDepartment of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, VA, USA.
Michael P AndreResearch Service, VA San Diego Healthcare System, San Diego, CA, USA.
Elisabeth OrozcoDepartment of Orthopaedic Surgery, University of California, San Diego, La Jolla, CA, USA.
Xin ChengResearch Service, VA San Diego Healthcare System, San Diego, CA, USA.
Eric Y ChangResearch Service, VA San Diego Healthcare System, San Diego, CA, USA.
Sameer B ShahDepartment of Bioengineering, University of California, San Diego, 9500 Gilman Drive, MC 0863, La Jolla, CA, 92093-0683, USA. sbshah@health.ucsd.edu.

Funding

Tumor Detection and Classification using QUS Technology's Structure FunctionR01CA226528 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI O'BRIEN, WILLIAM D. · 2019 to 2024
$2.3M
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Medical Imaging of Peripheral Nerve Injury and RepairI01CX002118 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI Sameer B. Shah · 2021 to 2026
–
CSRD VA I01 CX001388CSRD VA I01 CX002118NCI NIH HHS R01 CA226528
6 · The paper itself

Abstract

In this study, we evaluated the utility of using high-frequency ultrasound to non-invasively track the degenerative process in a rat model of peripheral nerve injury. Primary analyses explored spatial and temporal changes in quantitative backscatter coefficient (BSC) spectrum-based outcomes and B-mode textural outcomes, using gray level co-occurrence matrices (GLCMs), during the progressive transition from acute to chronic injury. As secondary analyses, correlations among GLCM and BSC spectrum-based parameters were evaluated, and immunohistochemistry were used to suggest a structural basis for ultrasound outcomes. Both mean BSC spectrum-based and mean GLCM-based measures exhibited significant spatial differences across presurgical and 1-month/2-month time points, distal stumps enclosed proximity to the injury site being particularly affected. The two sets of parameters sensitively detected peripheral nerve degeneration at 1-month and 2-month post-injury, with area under the receiver operating charactersitic curve > 0.8 for most parameters. The results also indicated that the many BSC spectrum-based and GLCM-based parameters significantly correlate with each other, and suggested a common structural basis for a diverse set of quantitative ultrasound parameters. The findings of this study suggest that BSC spectrum-based and GLCM-based analysis are promising non-invasive techniques for diagnosing peripheral nerve degeneration.

Indexed as

Nerve TissuePeripheral Nerve InjuriesAnimalsNerve DegenerationRatsSciatic NerveUltrasonography

Identifiers

PMID37980432
PMCPMC10657462

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.