Evidence map›Paper›PMID 37979008›Full record

Trial reportEuropean radiology2024

Reduction of contrast medium for transcatheter aortic valve replacement planning using a spectral detector CT: a prospective clinical trial.

Isabel L Langenbach, Marcel C Langenbach, Thomas Mayrhofer, Borek Foldyna, David Maintz, Konstantin Klein, Hendrik Wienemann, Kathrin B Krug, Martin Hellmich, Matti Adam and 1 more

Open access · hybridAbstract readClinical Trial
In one paragraph

Trial report in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 2 countries.

Isabel L Langenbach *Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA. ilangenbach@mgh.harvard.edu.ORCID http://orcid.org/0000-0001-7410-0635
Marcel C Langenbach *Cardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
Thomas MayrhoferCardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
Borek FoldynaCardiovascular Imaging Research Center, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, 165 Cambridge Street, Suite 400, Boston, MA, 02114, USA.
David MaintzInstitute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
Konstantin KleinInstitute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
Hendrik WienemannClinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany.
Kathrin B KrugInstitute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany.
Martin HellmichInstitute of Medical Statistics and Computational Biology, Medical Faculty, University of Cologne, Cologne, Germany.
Matti AdamClinic III for Internal Medicine, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany.
Claas P NaehleRadiologische Allianz, Hamburg, Germany.
Harvard University · USUniversity Hospital Cologne · DEUniversity of Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study investigated the use of dual-energy spectral detector computed tomography (CT) and virtual monoenergetic imaging (VMI) reconstructions in pre-interventional transcatheter aortic valve replacement (TAVR) planning. We aimed to determine the minimum required contrast medium (CM) amount to maintain diagnostic CT imaging quality for TAVR planning.

methodsIn this prospective clinical trial, TAVR candidates received a standardized dual-layer spectral detector CT protocol. The CM amount (Iohexol 350 mg iodine/mL, standardized flow rate 3 mL/s) was reduced systematically after 15 patients by 10 mL, starting at 60 mL (institutional standard). We evaluated standard, and 40- and 60-keV VMI reconstructions. For image quality, we measured signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and diameters in multiple vessel sections (i.e., aortic annulus: diameter, perimeter, area; aorta/arteries: minimal diameter). Mixed regression models (MRM), including interaction terms and clinical characteristics, were used for comparison.

resultsSixty consecutive patients (mean age, 79.4 ± 7.5 years; 28 females, 46.7%) were included. In pre-TAVR CT, the CM reduction to 40 mL is possible without affecting the image quality (MRM: SNR: -1.1, p = 0.726; CNR: 0.0, p = 0.999). VMI 40-keV reconstructions showed better results than standard reconstructions with significantly higher SNR (+ 6.04, p < 0.001). Reduction to 30 mL CM resulted in a significant loss of quality (MRM: SNR: -12.9, p < 0.001; CNR: -13.9, p < 0.001), regardless of the reconstruction. Across the reconstructions, we observed no differences in the metric evaluation (p > 0.914).

conclusionAmong TAVR candidates undergoing pre-interventional CT at a dual-layer spectral detector system, applying 40 mL CM is sufficient to maintain diagnostic image quality. VMI 40-keV reconstructions improve the vessel attenuation and are recommended for evaluation. CLINICAL RELEVANCE STATEMENT: Contrast medium reduction to 40 mL in pre-interventional transcatheter aortic valve replacement CT using dual-energy CT maintains image quality, while 40-keV virtual monoenergetic imaging reconstructions enhance vessel attenuation. These results offer valuable recommendations for interventional transcatheter aortic valve replacement evaluation and potentially improve nephroprotection in patients with compromised renal function. KEY POINTS: • Patients undergoing transcatheter aortic valve replacement (TAVR), requiring pre-interventional CT, are often multimorbid with impaired renal function. • Using a spectral detector dual-layer CT, contrast medium reduction to 40 mL is feasible, maintaining diagnostic image quality. • The additional application of virtual monoenergetic image reconstructions with 40 keV improves vessel attenuation significantly in clinical practice.

Indexed as

Contrast MediaTomography, X-Ray ComputedTranscatheter Aortic Valve ReplacementAgedAged, 80 and overAortic Valve StenosisFemaleHumansIohexolMaleProspective StudiesRadiographic Image Interpretation, Computer-AssistedSignal-To-Noise RatioContrast MediaIohexolAortic valveAortic valve stenosisContrast mediaTomography (X-ray computed)Transcatheter aortic valve replacement

Identifiers

PMID37979008
PMCPMC11166752
OpenAlexW4388793589

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked