Prototyping optimization-based image reconstructions from limited-angular-range data in dual-energy CT.

Buxin Chen, Zheng Zhang, Dan Xia, Emil Y Sidky, Xiaochuan Pan

Abstract read
In one paragraph

Article in Medical image analysis, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Buxin ChenDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Zheng ZhangDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Dan XiaDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Emil Y SidkyDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA.
Xiaochuan PanDepartment of Radiology, The University of Chicago, Chicago, IL 60637, USA; Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL 60637, USA. Electronic address: xpan@uchicago.edu.

Funding

Advanced iterative image reconstruction for digital breast tomosynthesis - Resubmission 01R01EB026282 · NIBIB · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN, SIDKY, EMIL Y · 2018 to 2021
$2.1M
Spectral CT metal artifact correctionR01EB023968 · NIBIB · MARQUETTE UNIVERSITY · PI SCHMIDT, TALY GILAT, SIDKY, EMIL Y · 2019 to 2022
$1.4M
Algorithm-Enabled Auto-Calibrating Quantitative Dual-Energy CTR21CA263660 · NCI · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN · 2022 to 2023
$414k
NCI NIH HHS R21 CA263660NIBIB NIH HHS R01 EB023968NIBIB NIH HHS R01 EB026282
6 · The paper itself

Abstract

Image reconstruction from data collected over full-angular range (FAR) in dual-energy CT (DECT) is well-studied. There exists interest in DECT with advanced scan configurations in which data are collected only over limited-angular ranges (LARs) for meeting unique workflow needs in certain practical imaging applications, and thus in the algorithm development for image reconstruction from such LAR data. The objective of the work is to investigate and prototype image reconstructions in DECT with LAR scans. We investigate and prototype optimization programs with various designs of constraints on the directional-total-variations (DTVs) of virtual monochromatic images and/or basis images, and derive the DTV algorithms to numerically solve the optimization programs for achieving accurate image reconstruction from data collected in a slew of different LAR scans. Using simulated and real data acquired with low- and high-kV spectra over LARs, we conduct quantitative studies to demonstrate and evaluate the optimization programs and their DTV algorithms developed. As the results of the numerical studies reveal, while the DTV algorithms yield images of visual quality and quantitative accuracy comparable to that of the existing algorithms from FAR data, the former reconstruct images with improved visualization, reduced artifacts, and also enhanced quantitative accuracy when applied to LAR data in DECT. Optimization-based, one-step algorithms, including the DTV algorithms demonstrated, can be developed for quantitative image reconstruction from spectral data collected over LARs of extents that are considerably smaller than the FAR in DECT. The theoretical and numerical results obtained can be exploited for prototyping designs of optimization-based reconstructions and LAR scans in DECT, and they may also yield insights into the development of reconstruction procedures in practical DECT applications. The approach and algorithms developed can naturally be applied to investigating image reconstruction from LAR data in multi-spectral and photon-counting CT.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsArtifactsHumansPhantoms, ImagingDirectional total variationDual-energy CTLimited angular rangePrototyping optimization-based reconstruction

Identifiers

PMID37976869
PMCPMC10872817

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.