Artificial intelligence-based analyses of varus leg alignment and after high tibial osteotomy show high accuracy and reproducibility.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.
- Artificial intelligence-based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Pooled it
- Precision of AI-Based Lower Limb Assessment in Children and Adolescents with Open Growth Plates.Diagnostics (Basel, Switzerland) · 2026Article
- [Artificial intelligence in musculoskeletal radiology : Current advances and emerging frontiers].Orthopadie (Heidelberg, Germany) · 2026Article
- Automated radiographic assessment of lower limb alignment using deep learning in a data-constrained clinical setting.BMC musculoskeletal disorders · 2025Article
- Artificial intelligence-guided assessment of the hip-knee-ankle angle shows excellent correlation with experienced human raters.Journal of experimental orthopaedics · 2025Article
- High accuracy in lower limb alignment analysis using convolutional neural networks, with improvements needed for joint-level metrics.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025Article
- Planning of distal femoral osteotomy - antegrade vs. retrograde miniaci method.Archives of orthopaedic and trauma surgery · 2025Article
- Frontal plane mechanical leg alignment estimation from knee x-rays using deep learning.Osteoarthritis and cartilage open · 2025Article
- Can Artificial Intelligence Reliably and Accurately Measure Lower Limb Alignment: A Systematic Review and Meta-Analysis.The archives of bone and joint surgery · 2025Review
- Article
- Evaluation of a deep learning software for automated measurements on full-leg standing radiographs.Knee surgery & related research · 2024Article
- Automated Measurements of Long Leg Radiographs in Pediatric Patients: A Pilot Study to Evaluate an Artificial Intelligence-Based Algorithm.Children (Basel, Switzerland) · 2024Article
- Joint line convergence angle is the most associated alignment factor with the severity of medial knee osteoarthritis.Journal of experimental orthopaedics · 2024Article
- Orthopaedic surgeons display a positive outlook towards artificial intelligence: A survey among members of the AGA Society for Arthroscopy and Joint Surgery.Journal of experimental orthopaedics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 3 countries.
Funding
Abstract
purposeThe aim of this study was to investigate the performance of an artificial intelligence (AI)-based software for fully automated analysis of leg alignment pre- and postoperatively after high tibial osteotomy (HTO) on long-leg radiographs (LLRs).
methodsLong-leg radiographs of 95 patients with varus malalignment that underwent medial open-wedge HTO were analyzed pre- and postoperatively. Three investigators and an AI software using deep learning algorithms (LAMA™, ImageBiopsy Lab, Vienna, Austria) evaluated the hip-knee-ankle angle (HKA), mechanical axis deviation (MAD), joint line convergence angle (JLCA), medial proximal tibial angle (MPTA), and mechanical lateral distal femoral angle (mLDFA). All measurements were performed twice and the performance of the AI software was compared with individual human readers using a Bayesian mixed model. In addition, the inter-observer intraclass correlation coefficient (ICC) for inter-observer reliability was evaluated by comparing measurements from manual readers. The intra-reader variability for manual measurements and the AI-based software was evaluated using the intra-observer ICC.
resultsInitial varus malalignment was corrected to slight valgus alignment after HTO. Measured by the AI algorithm and manually HKA (5.36° ± 3.03° and 5.47° ± 2.90° to - 0.70 ± 2.34 and - 0.54 ± 2.31), MAD (19.38 mm ± 11.39 mm and 20.17 mm ± 10.99 mm to - 2.68 ± 8.75 and - 2.10 ± 8.61) and MPTA (86.29° ± 2.42° and 86.08° ± 2.34° to 91.6 ± 3.0 and 91.81 ± 2.54) changed significantly from pre- to postoperative, while JLCA and mLDFA were not altered. The fully automated AI-based analyses showed no significant differences for all measurements compared with manual reads neither in native preoperative radiographs nor postoperatively after HTO. Mean absolute differences between the AI-based software and mean manual observer measurements were 0.5° or less for all measurements. Inter-observer ICCs for manual measurements were good to excellent for all measurements, except for JLCA, which showed moderate inter-observer ICCs. Intra-observer ICCs for manual measurements were excellent for all measurements, except for JLCA and for MPTA postoperatively. For the AI-aided analyses, repeated measurements showed entirely consistent results for all measurements with an intra-observer ICC of 1.0.
conclusionsThe AI-based software can provide fully automated analyses of native long-leg radiographs in patients with varus malalignment and after HTO with great accuracy and reproducibility and could support clinical workflows. LEVEL OF EVIDENCE: Diagnostic study, Level III.