Evidence map›Paper›PMID 37973974›Full record

ArticleKorean circulation journal2024

Risk of Atrial Fibrillation and Adverse Outcomes in Patients With Cardiac Implantable Electronic Devices.

So-Ryoung Lee, Ji Hyun Lee, Eue-Keun Choi, Eun-Kyung Jung, So-Jeong You, Seil Oh, Gregory Yh Lip

Open access · hybridAbstract read
In one paragraph

Article in Korean circulation journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Neuromodulation for Atrial Fibrillation Control.Korean circulation journal · 2024
    Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

So-Ryoung Lee *Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-6351-5015
Ji Hyun Lee *Department of Cardiology, Cardiovascular Center, Seoul National University Bundang Hospital, Seongnam, Korea.ORCID https://orcid.org/0000-0002-7162-1248
Eue-Keun ChoiDepartment of Internal Medicine, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-0411-6372
Eun-Kyung JungMedtronic Korea, Ltd., Seoul, Korea.
So-Jeong YouMedtronic Korea, Ltd., Seoul, Korea.ORCID https://orcid.org/0000-0002-3760-943X
Seil OhDepartment of Internal Medicine, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-2504-9615
Gregory Yh LipDepartment of Internal Medicine, Seoul National University Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0002-7566-1626
Seoul National University · KRMedtronic (South Korea) · KRSeoul National University Bundang Hospital · KRUniversity of Liverpool · GB

Funding

2016 SETAC Asia/Pacific ConferenceR13ES027302 · NIEHS · SOCIETY/ENVIRONMENTAL TOXICOLOGY/CHEM · PI MENZIE, CHARLES · 2016 to 2016
$6k
NIEHS NIH HHS 27302C0028
6 · The paper itself

Abstract

BACKGROUND AND

objectivesComprehensive epidemiological data are lacking on the incident atrial fibrillation (AF) in patients with cardiac implantable electronic devices (CIEDs). This study aimed to examine the incidence, risk factors, and AF-related adverse outcomes of patients with CIEDs.

methodsThis was an observational cohort study that analyzed patients without prevalent AF who underwent CIED implantation in 2009-2018 using a Korean nationwide claims database. The subjects were divided into three groups by CIED type and indication: pacemaker (n=21,438), implantable cardioverter defibrillator (ICD)/cardiac resynchronization therapy (CRT) with heart failure (HF) (n=3,450), and ICD for secondary prevention without HF (n=2,146). The incidence of AF, AF-associated predictors, and adverse outcomes were evaluated.

resultsDuring follow-up, the incidence of AF was 4.3, 7.3, and 5.1 per 100 person-years in the pacemaker, ICD/CRT with HF, and ICD without HF cohorts, respectively. Across the three cohorts, older age and valvular heart disease were commonly associated with incident AF. Incident AF was consistently associated with an increased risk of ischemic stroke (3.8-11.4-fold), admission for HF (2.6-10.5-fold), hospitalization for any cause (2.4-2.7-fold), all-cause death (4.1-5.0-fold), and composite outcomes (3.4-5.7-fold). Oral anticoagulation rates were suboptimal in patients with incident AF (pacemaker, 51.3%; ICD/CRT with HF, 51.7%; and ICD without HF, 33.8%, respectively).

conclusionsA substantial proportion of patients implanted CIED developed newly diagnosed AF. Incident AF was associated with a higher risk of adverse events. The importance of awareness, early detection, and appropriate management of AF in patients with CIED should be emphasized.

Indexed as

Atrial fibrillationCardiac resynchronization therapyImplantable cardioverter defibrillatorPacemakerRisk factor

Identifiers

PMID37973974
PMCPMC10784609
OpenAlexW4387818038

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.