Evidence map›Paper›PMID 37973963›Full record

ArticleScientific reports2023

New ex vivo method to objectively assess insulin spatial subcutaneous dispersion through time during pump basal-rate based administration.

Pauline Jacquemier, Yann Retory, Clara Virbel-Fleischman, Alexandra Schmidt, Agnes Ostertag, Martine Cohen-Solal, Fawaz Alzaid, Louis Potier, Jean-Baptiste Julla, Jean-François Gautier and 2 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Pauline JacquemierInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Yann RetoryLVL Médical Groupe, Lyon, France.
Clara Virbel-FleischmanCentre Explor, ALHIST - Air Liquide Healthcare, Bagneux, France.
Alexandra SchmidtCentre Explor, ALHIST - Air Liquide Healthcare, Bagneux, France.
Agnes OstertagUniversité Paris Cité, Inserm U1132 BIOSCAR, 75010, Paris, France.
Martine Cohen-SolalUniversité Paris Cité, Inserm U1132 BIOSCAR, 75010, Paris, France.
Fawaz AlzaidInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Louis PotierInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Jean-Baptiste JullaInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Jean-François GautierInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Nicolas VenteclefInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France.
Jean-Pierre RivelineInstitut Necker Enfants Malades (INEM), IMMEDIAB Laboratory, Université de Paris Cité, INSERM U1151, Paris, France. jeanpierre.riveline@aphp.fr.
Inserm · FRAir Liquide (France) · FRUniversité Paris-Sud · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Glycemic variability remains frequent in patients with type 1 diabetes treated with insulin pumps. Heterogeneous spreads of insulin infused by pump in the subcutaneous (SC) tissue are suspected but were barely studied. We propose a new real-time ex-vivo method built by combining high-precision imaging with simultaneous pressure measurements, to obtain a real-time follow-up of insulin subcutaneous propagation. Human skin explants from post-bariatric surgery are imaged in a micro-computed tomography scanner, with optimised parameters to reach one 3D image every 5 min during 3 h of 1UI/h infusion. Pressure inside the tubing is recorded. A new index of dispersion (IoD) is introduced and computed upon the segmented 3D insulin depot per time-step. Infusions were hypodermal in 58.3% among 24 assays, others being intradermal or extradermal. Several minor bubbles and one occlusion were observed. IoD increases with time for all injections. Inter-assay variability is the smallest for hypodermal infusions. Pressure elevations were observed, synchronised with air bubbles arrivals in the tissue. Results encourage the use of this method to compare infusion parameters such as pump model, basal rate, catheter characteristics, infusion site characteristics or patient phenotype.

Indexed as

Diabetes Mellitus, Type 1InsulinHumansHypoglycemic AgentsInsulin Infusion SystemsSubcutaneous TissueX-Ray MicrotomographyHypoglycemic AgentsInsulin

Identifiers

PMID37973963
PMCPMC10654403
OpenAlexW4388728286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.