Evidence map›Paper›PMID 37971627›Full record

ArticleMikrochimica acta2023

New method for measuring the pore sizes and pore size distributions of filter membranes-the fluorescence probe method.

Jiaying Zhu, Jinjie Wang, Hui Zhong, Yue Hu, Liqun Hu, Pinhua Rao, Rui Liu, Jun Zhu, Guanghui Li

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jiaying ZhuSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Jinjie WangSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China. jinjiewang@sues.edu.cn.ORCID http://orcid.org/0000-0002-2046-5716
Hui ZhongSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Yue HuSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Liqun HuSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Pinhua RaoSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Rui LiuSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China.
Jun ZhuNational Engineering Research Center for Nanotechnology, 28 East Jiangchuan Road, Shanghai, 200241, People's Republic of China.
Guanghui LiSchool of Chemistry and Chemical Engineering, Shanghai University of Engineering Science, 333 Longteng Road, Shanghai, 201620, People's Republic of China. 04190004@sues.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A novel, simple, and rapid method is demonstrated for measuring the pore size and pore size distribution of filtration membranes (FMs) used in aqueous applications with fluorescence probes. Because the selected fluorescent probes are mixable and have strong signals, combined with the operation of dead-end filtration, this method only requires small amounts of reagents; additionally, it is time-efficient by avoiding multiple rounds of filtration. This method detects the size of a FM pore throat (i.e., the narrowest position of a pore tunnel), which is more consistent with the actual filtration situation. The conditions, such as probe concentration, temperature, transmembrane pressure difference, and types of surfactants, have been optimized. The experimental results show that the fluorescence probe method has good accuracy and reproducibility for measuring the pore size and pore size distribution of both organic and inorganic FMs. The method is particularly suitable for rapid testing of the filtration performance (nominal pore size≥0.02 μm) of purchased or synthetic membranes in the laboratory.

Indexed as

Filter membraneFluorescence probePore sizePore size distribution

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.