Evidence map›Paper›PMID 37971534›Full record

ArticleStrahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al]2024

Comparison of patient setup accuracy for optical surface-guided and X-ray-guided imaging with respect to the impact on intracranial stereotactic radiotherapy.

Michael Schöpe, Jacob Sahlmann, Stefan Jaschik, Anne Findeisen, Gunther Klautke

Abstract read
PubMed Publisher
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Effects of intrafractional motion on targeting accuracy in frameless single-isocenter multi-target stereotactic radiosurgery.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Michael SchöpeDepartment of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
Jacob SahlmannDepartment of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
Stefan JaschikDepartment of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany. s.jaschik@skc.de.ORCID 0000-0003-3394-8511
Anne FindeisenDepartment of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
Gunther KlautkeDepartment of Radiation Oncology, Klinikum Chemnitz gGmbH, Bürgerstraße 2, 09113, Chemnitz, Germany.
Klinikum Chemnitz · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe objective of this work is to estimate the patient positioning accuracy of a surface-guided radiation therapy (SGRT) system using an optical surface scanner compared to an X‑ray-based imaging system (IGRT) with respect to their impact on intracranial stereotactic radiotherapy (SRT) and intracranial stereotactic radiosurgery (SRS).

methodsPatient positioning data, both acquired with SGRT and IGRT systems at the same linacs, serve as a basis for determination of positioning accuracy. A total of 35 patients with two different open face masks (578 datasets) were positioned using X‑ray stereoscopic imaging and the patient position inside the open face mask was recorded using SGRT. The measurement accuracy of the SGRT system (in a "standard" and an SRS mode with higher resolution) was evaluated using both IGRT and SGRT patient positioning datasets taking into account the measurement errors of the X‑ray system. Based on these clinically measured datasets, the positioning accuracy was estimated using Monte Carlo (MC) simulations. The relevant evaluation criterion, as standard of practice in cranial SRT, was the 95th percentile.

resultsThe interfractional measurement displacement vector of the SGRT system, σ

conclusionIn order to achieve the necessary geometric accuracy in cranial stereotactic radiotherapy, use of an X‑ray-based IGRT system, especially when treating with non-coplanar couch angles, is highly recommended.

Indexed as

RadiosurgeryRadiotherapy, Image-GuidedHumansImaging, Three-DimensionalPatient PositioningRadiographyRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsX-RaysClinical patient positioning dataImage guided radiotherapyMonte Carlo simulationPositioning accuracyStereotaxy

Identifiers

PMID37971534
OpenAlexW4388730096

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.