Evidence map›Paper›PMID 37970113›Full record

ArticleReumatologia2023

The 4DBODY system as a new tool for chest mobility assessment in patients with ankylosing spondylitis.

Teresa Sadura-Sieklucka, Daniel Szewczyk, Paweł Liberacki, Sławomir Paśko, Piotr Wojdasiewicz, Tomasz Targowski

Open access · diamondAbstract read
In one paragraph

Article in Reumatologia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Teresa Sadura-SiekluckaDepartment of Geriatrics, National Institute of Geriatrics, Rheumatology, and Rehabilitation, Warsaw, Poland.ORCID https://orcid.org/0000-0003-3698-8885
Daniel SzewczykDepartment of Geriatrics, National Institute of Geriatrics, Rheumatology, and Rehabilitation, Warsaw, Poland.ORCID https://orcid.org/0000-0001-7589-7391
Paweł LiberackiInstitute of Micromechanics and Photonics, Warsaw University of Technology, Poland.ORCID https://orcid.org/0000-0002-4072-7605
Sławomir PaśkoInstitute of Micromechanics and Photonics, Warsaw University of Technology, Poland.ORCID https://orcid.org/0000-0003-3817-2716
Piotr WojdasiewiczMedical University of Warsaw, Poland.ORCID https://orcid.org/0000-0003-3309-996X
Tomasz TargowskiDepartment of Geriatrics, National Institute of Geriatrics, Rheumatology, and Rehabilitation, Warsaw, Poland.ORCID https://orcid.org/0000-0002-0008-1256
National Institute of Geriatrics, Rheumatology and Rehabilitation · PLWarsaw University of Technology · PLMedical University of Warsaw · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Ankylosing spondylitis (AS) is a chronic inflammatory, progressive disease, which leads to deterioration of chest and spine mobility and decrease of physical capacity with abnormal chest movement patterns. We aimed to assess the usefulness of the 4DBODY technology for evaluation of the effectiveness of AS treatment. Material and methods: The 4DBODY technology was assessed on single AS patient with axial involvement. The patient was examined twice, before and after 14 days of rehabilitation. Physiotherapeutic and plethysmographic examinations were used, as well as angular measurement of spine curvatures and measurement of chest mobility. Chest activity measured using the 4DBODY system and the quality of movement were visualized. Results: There was observed an increase of chest mobility from 18 mm to 27.9 mm (up 55%) in the 4DBODY system measurement. The quality of the chest movement also improved, the required phases of inspiration were synchronized. The angular position of the spine has also changed. The chest expansion improved from 25 mm to 50 mm measured on the level of the fourth intercostal space and from 30 mm to 50 mm at the Th10 level. Inspiratory and expiratory muscle strength increased respectively from 80% to 93% and from 46% to 86% of the predicted values. Total airway resistance (Rtot) - increase from 59% to 67%, whereas functional residual capacity (FRC) and total lung capacity (TLC) did not change significantly. Conclusions: The new 4DBODY technology was found to be an effective method of examination and assessment of the effectiveness of rehabilitation of patients with AS.

Indexed as

ankylosing spondylitischest mobilityrehabilitationthe 4DBODY system

Identifiers

PMID37970113
PMCPMC10634404
OpenAlexW4388079694

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.