ArticleCJC pediatric and congenital heart disease2023
Automatic Prediction of Paediatric Cardiac Output From Echocardiograms Using Deep Learning Models.
Article in CJC pediatric and congenital heart disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Multi-task artificial intelligence annotation of echocardiographic images: a retrospective multi-cohort study.medRxiv : the preprint server for health sciences · 2026Article
- Artificial Intelligence in Fetal and Pediatric Echocardiography.Children (Basel, Switzerland) · 2024Review
Corrections and comments
- Erratum issuedErratum.2023
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Cardiac output (CO) perturbations are common and cause significant morbidity and mortality. Accurate CO assessment is crucial for guiding treatment in anaesthesia and critical care, but measurement is difficult, even for experts. Artificial intelligence methods show promise as alternatives for accurate, rapid CO assessment. Methods: We reviewed paediatric echocardiograms with normal CO and a dilated cardiomyopathy patient group with reduced CO. Experts measured the left ventricular outflow tract diameter, velocity time integral, CO, and cardiac index (CI). EchoNet-Dynamic is a deep learning model for estimation of ejection fraction in adults. We modified this model to predict the left ventricular outflow tract diameter and retrained it on paediatric data. We developed a novel deep learning approach for velocity time integral estimation. The combined models enable automatic prediction of CO. We evaluated the models against expert measurements. Primary outcomes were root-mean-squared error, mean absolute error, mean average percentage error, and coefficient of determination ( Results: In a test set unused during training, CI was estimated with the root-mean-squared error of 0.389 L/min/m Conclusions: Our model estimated CO with strong correlation to ground truth and a bias of 0.17 L/min, better than many CO measurements in paediatrics. Model pretraining enabled accurate estimation despite a small dataset. Potential uses include supporting clinicians in real-time bedside calculation of CO, identification of low-CO states, and treatment responses.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.