ArticleJSES international2023
The base plate orientation angle: a plain radiographic technique for designing the base plate's inclination in reverse shoulder arthroplasty.
Article in JSES international, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 2 citations in OpenAlex.
- Robotic assistance improves reproducibility of planned glenoid baseplate inclination in reverse shoulder arthroplasty.International orthopaedics · 2026Article
- Customized positioning of the glenoid component in reverse shoulder arthroplasty: a new computer aided design methodology.International orthopaedics · 2026Article
- The reverse shoulder arthroplasty angle may contribute to overt inferior inclination: comparison with alternative parameters.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- The acetabularization index: a novel measure of acromial bone loss prior to reverse shoulder arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Superior inclination of the base plate in reverse shoulder arthroplasty (RSA) is underestimated and may lead to major setbacks in terms of functional outcomes due to the altered biomechanics. Joint instability, scapular notching, and loosening of the glenoid component are considered the most serious sequelae. Therefore, a thorough preoperative radiological assessment of the affected shoulder joint and customized design of the prosthesis according to the glenoid morphology are decisive and directly correlated to the outcome. In this article, we propose a simple radiographic technique to assess the inclination of the glenoid preoperatively, which identifies the need for intraoperative correction. Materials and Methods: One hundred inconspicuous shoulder radiographs were included in the control group (CG) to define the normal ranges of the base plate orientation angle (BOA) and the base plate correction angle (BCA). Further, both angles were measured on 2-dimensional (2D) computed tomography scans of patients with proximal humerus fractures as well as radiographs, 2D and 3-dimensional (3D) computed tomography scans of patients with cuff tear arthropathy who underwent RSA between 2018 and 2021. The interobserver reliability among three independent testers was evaluated by calculating the intraclass correlation coefficient. In cuff tear arthropathy cases, the BOA and BCA measurements on different imaging modalities were compared using the Wilcoxon test. Possible variations of both angles' values based on glenoid erosion types, according to the Favard classification, were also investigated. Results: Regardless of the imaging modality used, the interobserver reliability was excellent among three independent observers. In the CG, the mean BOA and BCA values were 118° ± 6° and 17° ± 5°, respectively. The mean corrected BOA values of the CG and fracture group were 136° ± 5° and 140° ± 5°, respectively. In contrast to the BCA values, the BOA measurements on radiographs showed a statistically significant difference compared to those obtained on 2D- and 3D scans in the cuff arthropathy group. Further, both angles' values varied according to the extent and location of the glenoid erosion. The lowest mean BOA and highest mean BCA values were observed in cases with Favard glenoid type E3. Conclusions: The BOA and the BCA are reliable tools proposed to aid in precisely positioning the glenoid component in RSA in the preoperative setting. Whereas, the BOA determines the inclination of the inferior glenoid segment, the BCA represents the extent of correction required to obtain a neutral inclination of the base plate. Glenoid type E3 of the Favard classification with superior wear is particularly susceptible to base plate superior tilt.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.