Evidence map›Paper›PMID 37969484›Full record

ArticleCJC pediatric and congenital heart disease2022

Balloon Atrial Septostomy: Does the Balloon Size Matter?

Jawad Al-Kassmy, Iñaki Navarro-Castellanos, Francisco Gonzalez Barlatay, Joaquim Miró, Nagib Dahdah

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in CJC pediatric and congenital heart disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Balloon Atrial Septostomy: The Balloon Size Doesn't Matter?!CJC pediatric and congenital heart disease · 2022
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 3 countries.

Jawad Al-KassmyRoyal College of Surgeons in Ireland, School of Medicine, Dublin, Ireland.
Iñaki Navarro-CastellanosDepartment of Paediatrics, Division of Paediatric Cardiology, Sainte-Justine University Hospital Center, Montréal, Québec, Canada.
Francisco Gonzalez BarlatayDepartment of Paediatrics, Division of Paediatric Cardiology, Bristol Royal Hospital for Children, Bristol, United Kingdom.
Joaquim MiróDepartment of Paediatrics, Division of Paediatric Cardiology, Sainte-Justine University Hospital Center, Montréal, Québec, Canada.
Nagib DahdahDepartment of Paediatrics, Division of Paediatric Cardiology, Sainte-Justine University Hospital Center, Montréal, Québec, Canada.
Centre Hospitalier Universitaire Sainte-Justine · CABristol Royal Hospital for Children · GBRoyal College of Surgeons in Ireland · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dextro-transposition of the great arteries is a congenital heart defect with eventually lethal life-threatening consequences of hypoxic low cardiac output. When a balloon atrial septostomy (BAS) is needed, it is performed shortly after birth to create an interatrial shunt and improve systemic blood oxygenation and haemodynamic conditions. In 2019 and 2020, the withdrawal of some balloon atrioseptostomy catheters from the market led to increased use of catheters with different materials, shapes, and sizes. The main objective of this study was to investigate whether the size of the Miller and Fogarty balloon (Edwards Lifesciences) in its 2 variations, the 4.0 cc and the 1.8 cc, had a different impact on the systemic oxygen saturation, on the atrial septal defect (ASD) size, or on the type and frequency of procedure-related complications. Methods: We conducted a retrospective study on 134 consecutive patients diagnosed with dextrotransposition of the great arteries between 2002 and 2018 who underwent BAS in a tertiary paediatric hospital in Canada. Results: BAS resulted in a significant increase in oxygen saturation of 18.91% ± 12.95% points ( Conclusions: This is the first study to show that the small balloon is as efficient as the large balloon catheter including in premature patients. This raises the question whether different balloon sizes are necessary.

Identifiers

PMID37969484
PMCPMC10642134
OpenAlexW4307724475

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.