Evidence map›Paper›PMID 37969228›Full record

ArticleJournal of orthopaedics2023

Patient-reported and radiographic outcomes of a porous-coated acetabular cup in robotic assisted total hip arthroplasty at 2-year follow up.

Robert C Marchand, Kevin Marchand, Kelly Taylor, Zachary Guerrieo, Daniel Hameed, Sandeep S Bains, Jeremy A Dubin, Nipun Sodhi, Michael A Mont

Open access · greenAbstract read
In one paragraph

Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Observational
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Robert C MarchandSouth County Orthopaedics, Orthopaedics Rhode Island, Wakefield, RI, USA.
Kevin MarchandNorthwell Health Orthopedics, Lenox Hill Hospital, New York, NY, USA.
Kelly TaylorSouth County Orthopaedics, Orthopaedics Rhode Island, Wakefield, RI, USA.
Zachary GuerrieoSouth County Orthopaedics, Orthopaedics Rhode Island, Wakefield, RI, USA.
Daniel HameedLifeBridge Health, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, MD, USA.
Sandeep S BainsLifeBridge Health, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, MD, USA.
Jeremy A DubinLifeBridge Health, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, MD, USA.
Nipun SodhiDepartment of Orthopaedic Surgery, Lenox Hill Hospital Northwell Health, New York, NY, USA.
Michael A MontLifeBridge Health, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, MD, USA.
Sinai Hospital · USSouth County Hospital · USNorthwell Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Several implant manufacturers have developed ultra-porous metal substrate acetabular components recently. Despite this, data on clinical and radiographic outcomes remain limited. Our study evaluated postoperative patient-reported outcome measures (PROMs) and radiographic analyses in patients fitted with a novel acetabular porous-coated component. Methods: A total of 152 consecutive patients underwent a total hip arthroplasty by a single orthopaedic surgeon. All patients underwent surgery utilizing the same CT-scan based robotic-assisted device with the same porous cementless acetabular shell. They received standardized postoperative physical therapy, rehabilitation, and pain protocols. Preoperatively, first postoperative visit, 6-months, 1-year, and 2-years, patients were evaluated based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain, physical function, and total scores; 2) Patient-Reported Outcomes Measurement Information System (PROMIS)-10 physical and mental scores; 3) Hip Disability and Osteoarthritis Outcome Score (HOOS)-Jr scores; as well as 4) acetabular component positions and 5) evidence of acetabular component loosening. Results: Significant improvements were observed by 6 months in WOMAC pain, physical function, and total scores (p < 0.05), maintained at 1 and 2 years. PROMIS-10 physical scores also improved significantly from preoperative to 6 months postoperative and remained so at 1 and 2 years postoperative (p < 0.05). No significant changes were found in PROMIS-10 mental scores. HOOS-Jr scores significantly improved from preoperative to 6 months postoperative and remained so through 2 years (p < 0.05). At 6 months, slight changes were noted in abduction angle and horizontal and vertical offset. Radiolucencies, initially found in 3 shells, reduced to 1 shell with 2 new radiolucencies by 6 months, and remained stable with no subsequent operative interventions. At 1 year and 2 years, no radiographic abnormalities were noted, including complete resolution of prior radiolucencies as well as stable components. Conclusion: This porous cementless acetabular shell, implanted with CT-scan-based robotic-assisted techniques, demonstrated excellent postoperative PROMs at 2 years. Stable radiolucencies suggest good component stability. The early stable clinical and radiographic results suggest promising long-term outcomes with this device. Level of evidence: III (retrospective cohort study).

Indexed as

Acetabular componentsAcetabular porous-coated componentClinical outcomesOrthopaedic surgeonPostoperative patient reported outcome measuresRadiographic outcomesTotal hip arthroplastyUltra-porous metal substrate

Identifiers

PMID37969228
PMCPMC10643097
OpenAlexW4387378390

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.