Patient-reported and radiographic outcomes of a porous-coated acetabular cup in robotic assisted total hip arthroplasty at 2-year follow up.
Article in Journal of orthopaedics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Comparison of accuracy of acetabular cup placement using manual versus robotic-assistance in the same patient cohort undergoing robotic-assisted total hip arthroplasty.Journal of robotic surgery · 2026Observational
- Robotic assistance is associated with improved surgical efficiency during direct anterior total hip arthroplasty.Journal of orthopaedics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Several implant manufacturers have developed ultra-porous metal substrate acetabular components recently. Despite this, data on clinical and radiographic outcomes remain limited. Our study evaluated postoperative patient-reported outcome measures (PROMs) and radiographic analyses in patients fitted with a novel acetabular porous-coated component. Methods: A total of 152 consecutive patients underwent a total hip arthroplasty by a single orthopaedic surgeon. All patients underwent surgery utilizing the same CT-scan based robotic-assisted device with the same porous cementless acetabular shell. They received standardized postoperative physical therapy, rehabilitation, and pain protocols. Preoperatively, first postoperative visit, 6-months, 1-year, and 2-years, patients were evaluated based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain, physical function, and total scores; 2) Patient-Reported Outcomes Measurement Information System (PROMIS)-10 physical and mental scores; 3) Hip Disability and Osteoarthritis Outcome Score (HOOS)-Jr scores; as well as 4) acetabular component positions and 5) evidence of acetabular component loosening. Results: Significant improvements were observed by 6 months in WOMAC pain, physical function, and total scores (p < 0.05), maintained at 1 and 2 years. PROMIS-10 physical scores also improved significantly from preoperative to 6 months postoperative and remained so at 1 and 2 years postoperative (p < 0.05). No significant changes were found in PROMIS-10 mental scores. HOOS-Jr scores significantly improved from preoperative to 6 months postoperative and remained so through 2 years (p < 0.05). At 6 months, slight changes were noted in abduction angle and horizontal and vertical offset. Radiolucencies, initially found in 3 shells, reduced to 1 shell with 2 new radiolucencies by 6 months, and remained stable with no subsequent operative interventions. At 1 year and 2 years, no radiographic abnormalities were noted, including complete resolution of prior radiolucencies as well as stable components. Conclusion: This porous cementless acetabular shell, implanted with CT-scan-based robotic-assisted techniques, demonstrated excellent postoperative PROMs at 2 years. Stable radiolucencies suggest good component stability. The early stable clinical and radiographic results suggest promising long-term outcomes with this device. Level of evidence: III (retrospective cohort study).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials