SynthesisThe Cochrane database of systematic reviews2023
Artificial intelligence for detecting keratoconus.
Synthesis in The Cochrane database of systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 5 syntheses or guidelines pooled it, 25 citations in OpenAlex.
- Association Between Keratoconus and Inflammatory Bowel Disease: A Systematic Review and Meta-Analysis.Cornea · 2026Pooled it
- Early Detection of Keratoconus: Diagnostic Advances and Their Impact on Visual Outcomes: A Systematic Review.Medicina (Kaunas, Lithuania) · 2025Pooled it
- Artificial intelligence for glaucoma.The Cochrane database of systematic reviews · 2025Pooled it
- Artificial intelligence for diagnosing exudative age-related macular degeneration.The Cochrane database of systematic reviews · 2024Pooled it
- Artificial intelligence for detecting keratoconus.The Cochrane database of systematic reviews · 2023Pooled it
- Smartphone-Assisted Placido Ring Imaging for K1 Stratification in Keratoconus: A Deep Learning Study.Diagnostics (Basel, Switzerland) · 2026Article
- Nanomaterial-Enhanced Corneal Cross-Linking: Engineering Strategies for Transforming Keratoconus Management.Pharmaceutics · 2026Review
- Development of a multimodal large language model for early warning and diagnosis of chronic ocular GVHD.NPJ digital medicine · 2026Article
- Motion-Tracking Brillouin Microscopy for Keratoconus Suspect Identification: Comparison With Multimodal Corneal Imaging.American journal of ophthalmology · 2026Article
- Transepithelial corneal cross-linking: a review.International ophthalmology · 2026Review
- Enhancing the diagnostic precision of subclinical keratoconus by combining indices from Scheimpflug tomography, corneal biomechanics, and anterior segment optical coherence tomography.International journal of ophthalmology · 2026Article
- Enhanced Imaging of Ocular Surface Lesions.Journal of clinical medicine · 2025Review
- Integration of tear fluid biomarkers and machine learning for the early detection of keratoconus.BMC ophthalmology · 2025Article
- Neural Network Prediction of Keratoconus in AIPL1-Linked Leber Congenital Amaurosis: A Proof-of-Concept Pilot Study.Journal of clinical medicine · 2025Article
- Clinical Applications of Artificial Intelligence in Corneal Diseases.Vision (Basel, Switzerland) · 2025Review
- Understanding the relationship between astigmatism, posterior cornea and corneal thickness: a move to total corneal power.Eye (London, England) · 2025Article
- Early diagnosis of keratoconus using corneal biomechanics and OCT derived technologies.Eye and vision (London, England) · 2025Review
- Artificial Intelligence Applications in Ophthalmology.JMA journal · 2025Review
- Strategies for Early Keratoconus Diagnosis: A Narrative Review of Evaluating Affordable and Effective Detection Techniques.Journal of clinical medicine · 2025Review
- Artificial intelligence in ophthalmology: opportunities, challenges, and ethical considerations.Medical hypothesis, discovery & innovation ophthalmology journal · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundKeratoconus remains difficult to diagnose, especially in the early stages. It is a progressive disorder of the cornea that starts at a young age. Diagnosis is based on clinical examination and corneal imaging; though in the early stages, when there are no clinical signs, diagnosis depends on the interpretation of corneal imaging (e.g. topography and tomography) by trained cornea specialists. Using artificial intelligence (AI) to analyse the corneal images and detect cases of keratoconus could help prevent visual acuity loss and even corneal transplantation. However, a missed diagnosis in people seeking refractive surgery could lead to weakening of the cornea and keratoconus-like ectasia. There is a need for a reliable overview of the accuracy of AI for detecting keratoconus and the applicability of this automated method to the clinical setting.
objectivesTo assess the diagnostic accuracy of artificial intelligence (AI) algorithms for detecting keratoconus in people presenting with refractive errors, especially those whose vision can no longer be fully corrected with glasses, those seeking corneal refractive surgery, and those suspected of having keratoconus. AI could help ophthalmologists, optometrists, and other eye care professionals to make decisions on referral to cornea specialists. Secondary objectives To assess the following potential causes of heterogeneity in diagnostic performance across studies. • Different AI algorithms (e.g. neural networks, decision trees, support vector machines) • Index test methodology (preprocessing techniques, core AI method, and postprocessing techniques) • Sources of input to train algorithms (topography and tomography images from Placido disc system, Scheimpflug system, slit-scanning system, or optical coherence tomography (OCT); number of training and testing cases/images; label/endpoint variable used for training) • Study setting • Study design • Ethnicity, or geographic area as its proxy • Different index test positivity criteria provided by the topography or tomography device • Reference standard, topography or tomography, one or two cornea specialists • Definition of keratoconus • Mean age of participants • Recruitment of participants • Severity of keratoconus (clinically manifest or subclinical) SEARCH
methodsWe searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register), Ovid MEDLINE, Ovid Embase, OpenGrey, the ISRCTN registry, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform (WHO ICTRP). There were no date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 29 November 2022. SELECTION CRITERIA: We included cross-sectional and diagnostic case-control studies that investigated AI for the diagnosis of keratoconus using topography, tomography, or both. We included studies that diagnosed manifest keratoconus, subclinical keratoconus, or both. The reference standard was the interpretation of topography or tomography images by at least two cornea specialists. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted the study data and assessed the quality of studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. When an article contained multiple AI algorithms, we selected the algorithm with the highest Youden's index. We assessed the certainty of evidence using the GRADE approach. MAIN
resultsWe included 63 studies, published between 1994 and 2022, that developed and investigated the accuracy of AI for the diagnosis of keratoconus. There were three different units of analysis in the studies: eyes, participants, and images. Forty-four studies analysed 23,771 eyes, four studies analysed 3843 participants, and 15 studies analysed 38,832 images. Fifty-four articles evaluated the detection of manifest keratoconus, defined as a cornea that showed any clinical sign of keratoconus. The accuracy of AI seems almost perfect, with a summary sensitivity of 98.6% (95% confidence interval (CI) 97.6% to 99.1%) and a summary specificity of 98.3% (95% CI 97.4% to 98.9%). However, accuracy varied across studies and the certainty of the evidence was low. Twenty-eight articles evaluated the detection of subclinical keratoconus, although the definition of subclinical varied. We grouped subclinical keratoconus, forme fruste, and very asymmetrical eyes together. The tests showed good accuracy, with a summary sensitivity of 90.0% (95% CI 84.5% to 93.8%) and a summary specificity of 95.5% (95% CI 91.9% to 97.5%). However, the certainty of the evidence was very low for sensitivity and low for specificity. In both groups, we graded most studies at high risk of bias, with high applicability concerns, in the domain of patient selection, since most were case-control studies. Moreover, we graded the certainty of evidence as low to very low due to selection bias, inconsistency, and imprecision. We could not explain the heterogeneity between the studies. The sensitivity analyses based on study design, AI algorithm, imaging technique (topography versus tomography), and data source (parameters versus images) showed no differences in the results. AUTHORS'
conclusionsAI appears to be a promising triage tool in ophthalmologic practice for diagnosing keratoconus. Test accuracy was very high for manifest keratoconus and slightly lower for subclinical keratoconus, indicating a higher chance of missing a diagnosis in people without clinical signs. This could lead to progression of keratoconus or an erroneous indication for refractive surgery, which would worsen the disease. We are unable to draw clear and reliable conclusions due to the high risk of bias, the unexplained heterogeneity of the results, and high applicability concerns, all of which reduced our confidence in the evidence. Greater standardization in future research would increase the quality of studies and improve comparability between studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.