A simplified low-cost phantom for image quality assessment of dental cone beam computed tomography unit.

James Anthony Rabba, Hanis Arina Jaafar, Fatanah Mohamad Suhaimi, Mohd Zubir Mat Jafri, Noor Diyana Osman

Abstract read
In one paragraph

Article in Journal of medical radiation sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

James Anthony RabbaAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
Hanis Arina JaafarAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
Fatanah Mohamad SuhaimiAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.
Mohd Zubir Mat JafriSchool of Physics, Universiti Sains Malaysia, Penang, Malaysia.
Noor Diyana OsmanAdvanced Medical and Dental Institute, Universiti Sains Malaysia, Penang, Malaysia.ORCID https://orcid.org/0000-0002-3846-5116

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionA standardised testing protocol for evaluation of a wide range of dental cone beam computed tomography (CBCT) performance and image quality (IQ) parameters is still limited and commercially available testing tool is unaffordable by some centres. This study aims to assess the performance of a low-cost fabricated phantom for image quality assessment (IQA) of digital CBCT unit.

methodsA customised polymethyl methacrylate (PMMA) cylindrical phantom was developed for performance evaluation of Planmeca ProMax 3D Mid digital dental CBCT unit. The fabricated phantom consists of four different layers for testing specific IQ parameters such as CT number accuracy and uniformity, noise and CT number linearity. The phantom was scanned using common scanning protocols in clinical routine (90.0 kV, 8.0 mA and 13.6 s). In region-of-interest (ROI) analysis, the mean CT numbers (in Hounsfield unit, HU) and noise for water and air were determined and compared with the reference values (0 HU for water and -1000 HU for air). For linearity test, the correlation between the measured HU of different inserts with their density was studied.

resultsThe average CT number were -994.1 HU and -2.4 HU, for air and water, respectively and the differences were within the recommended acceptable limit. The linearity test showed a strong positive correlation (R

conclusionThe fabricated IQ phantom serves as a simple and affordable testing tool for digital dental CBCT imaging.

Indexed as

Cone-Beam Computed TomographyPolymethyl MethacrylateImage Processing, Computer-AssistedPhantoms, ImagingWaterPolymethyl MethacrylateWaterCone-beam computed tomographydental digital radiographydiagnostic imagingimaging phantomsquality control

Identifiers

PMID37965811
PMCPMC10920926

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.