Evidence map›Paper›PMID 37965324›Full record

ArticleFrontiers in immunology2023

Vaccine-induced SARS-CoV-2 antibody response: the comparability of S1-specific binding assays depends on epitope and isotype discrimination.

Silvia Schest, Claus Langer, Yuriko Stiegler, Bianca Karnuth, Jan Arends, Hugo Stiegler, Thomas Masetto, Christoph Peter, Matthias Grimmler

Open access · goldAbstract read
In one paragraph

Article in Frontiers in immunology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Silvia SchestMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Claus LangerMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Yuriko StieglerMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Bianca KarnuthMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Jan ArendsMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Hugo StieglerMedizinisches Versorgungszentrum für Labormedizin und Mikrobiologie Ruhr GmbH, Essen, Germany.
Thomas MasettoInstitute of Molecular Medicine I, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Christoph PeterInstitute of Molecular Medicine I, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Matthias GrimmlerDiaSys Diagnostic Systems GmbH, Holzheim, Germany.
Center for HIV and Hepatogastroenterology · DEHeinrich Heine University Düsseldorf · DEHochschule Fresenius · DEUniversity of Applied Sciences Tyrol · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Quantification of the SARS-CoV-2-specific immune response by serological immunoassays is critical for the management of the COVID-19 pandemic. In particular, neutralizing antibody titers to the viral spike (S) protein have been proposed as a correlate of protection (CoP). The WHO established the First International Standard (WHO IS) for anti-SARS-CoV-2 immunoglobulin (Ig) (NIBSC 20/136) to harmonize binding assays with the same antigen specificity by assigning the same unitage in binding antibody units (BAU)/ml. Method: In this study, we analyzed the S1-specific antibody response in a cohort of healthcare workers in Germany (n = 76) during a three-dose vaccination course over 8.5 months. Subjects received either heterologous or homologous prime-boost vaccination with ChAdOx1 nCoV-19 (AstraZeneca) and BNT162b2 (Pfizer-BioNTech) or three doses of BNT162b2. Antibodies were quantified using three anti-S1 binding assays (ELISA, ECLIA, and PETIA) harmonized to the WHO IS. Serum levels of neutralizing antibodies were determined using a surrogate virus neutralization test (sVNT). Binding assays were compared using Spearman's rank correlation and Passing-Bablok regression. Findings: All assays showed good correlation and similar antibody kinetics correlating with neutralizing potential. However, the assays show large proportional differences in BAU/ml. ECLIA and PETIA, which detect total antibodies against the receptor- binding domain (RBD) within the S1 subunit, interact similarly with the convalescent plasma-derived WHO IS but differently with vaccine serum, indicating a high sensitivity to the IgG/IgM/IgA ratio. Conclusion: All three binding assays allow monitoring of the antibody response in COVID-19-vaccinated individuals. However, the assay-specific differences hinder the definition of a common protective threshold in BAU/ml. Our results highlight the need for the thoughtful use of conversion factors and consideration of method-specific differences. To improve the management of future pandemics and harmonize total antibody assays, we should strive for reference material with a well-characterized Ig isotype composition.

Indexed as

COVID-19VaccinesAntibodies, ViralBNT162 VaccineChAdOx1 nCoV-19COVID-19 SerotherapyEpitopesHumansImmunoglobulin IsotypesPandemicsSARS-CoV-2Antibodies, ViralBNT162 VaccineChAdOx1 nCoV-19EpitopesImmunoglobulin IsotypesVaccinescorrelate of protectionCOVID-19 vaccineshumoral immune responseneutralizing antibodiesSARS-CoV-2 antibodyserological testingspike proteinWHO standard

Identifiers

PMID37965324
PMCPMC10641008
OpenAlexW4387955952

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.