In one paragraph

Article in Arthroplasty (London, England), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 2 pooled it
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 syntheses or guidelines pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Timothy McAleeseRCSI University of Medicine and Health Sciences, Dublin, D02 YN77, Ireland. timmcaleese@rcsi.ie.ORCID http://orcid.org/0000-0001-9713-9057
Tiarnán Ó DoinnDepartment of Trauma and Orthopaedics, Tallaght University Hospital, Dublin, D24 NR04, Ireland.
James M BroderickDepartment of Trauma and Orthopaedics, Tallaght University Hospital, Dublin, D24 NR04, Ireland.
Ross FarringtonDepartment of Microbiology, Tallaght University Hospital, Dublin, D24 NR04, Ireland.
Anna-Rose PriorDepartment of Microbiology, Tallaght University Hospital, Dublin, D24 NR04, Ireland.
John F QuinlanDepartment of Trauma and Orthopaedics, Tallaght University Hospital, Dublin, D24 NR04, Ireland.
Tallaght University Hospital · IERoyal College of Surgeons in Ireland · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe incidence of prosthetic joint infection (PJI) is increasing, coincident with the rising volume of joint arthroplasty being performed. With recent controversy regarding the efficacy of surgical helmet systems (SHS) in preventing infection, the focus has turned to the correct donning techniques and usage of surgical hoods. The aim of this study was to compare the bacterial contamination of the operating surgeon's gloves after two common donning techniques of SHS hoods. We also evaluated the baseline sterility of the SHS hoods at the beginning of the procedure.

methodsThe bacterial contamination rate was quantified using colony-forming units (CFUs), with 50 trials performed per donning technique. Samples were cultured on 5% Columbia blood agar in ambient air at 37 °C for 48 h and all subsequent bacterial growth was identified using a MALDI-TOF mass spectrometer. In Group 1, the operating surgeon donned their colleague's hood. In Group 2, the operating surgeon had their hood applied by a non-scrubbed colleague. After each trial, the operating surgeon immediately inoculated their gloves onto an agar plate. The immediate sterility of 50 SHS hoods was assessed at two separate zones-the screen (Zone 1) and the neckline (Zone 2).

resultsThere was no significant difference in contamination rates between the two techniques (3% vs. 2%, P = 0.99) or between right and left glove contamination rates. Immediately after donning, 6/50 (12%) of SHS hoods cultured an organism. Contamination rates at both the face shield and neckline zones were equivalent. The majority of bacteria cultured were Bacillus species. DISCUSSION: We found no significant difference in the operating surgeon's glove contamination using two common SHS hood-donning techniques when they were performed under laminar airflow with late fan activation. We suggest the SHS hood should not be assumed to be completely sterile and that gloves are changed if it is touched intraoperatively.

Indexed as

ArthroplastyDonningPeriprosthetic joint infectionSterile surgical fieldSurgical helmet systems

Identifiers

PMID37964378
PMCPMC10647130
OpenAlexW4388682532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.