Evidence map›Paper›PMID 37964127›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Single-incision bone bridge lateral meniscus allograft transplantation: preserving neurovascular safety with promising results for posterior horn distortion and graft maturation.

JiHwan Lee, Dhong Won Lee, Tae Hyun Kyeong, Jung Wook Lee, Jin Goo Kim

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

JiHwan LeeDepartment of Orthopedic Surgery, Myongji Hospital, 55, Hwasu-Ro 14Beon-Gil, Deogyang-Gu, Goyang-Si, Gyeonggi-Do, 10475, South Korea.
Dhong Won LeeDepartment of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, South Korea.
Tae Hyun KyeongDepartment of Orthopedic Surgery, Myongji Hospital, 55, Hwasu-Ro 14Beon-Gil, Deogyang-Gu, Goyang-Si, Gyeonggi-Do, 10475, South Korea.
Jung Wook LeeDepartment of Orthopedic Surgery, Myongji Hospital, 55, Hwasu-Ro 14Beon-Gil, Deogyang-Gu, Goyang-Si, Gyeonggi-Do, 10475, South Korea.
Jin Goo KimDepartment of Orthopedic Surgery, Myongji Hospital, 55, Hwasu-Ro 14Beon-Gil, Deogyang-Gu, Goyang-Si, Gyeonggi-Do, 10475, South Korea. jgkim107@msn.com.ORCID http://orcid.org/0000-0001-5869-1893
Myongji Hospital · KRKonkuk University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to investigate the graft maturation and safety of single-incision bone bridge lateral meniscus allograft transplantation (LMAT).

methodsThis study involved 35 patients who underwent LMAT between 2019 and 2020. All patients completed at least 2 years of follow-up (median 34 months; range 24-43) and underwent preoperative magnetic resonance imaging (MRI) to assess the trajectory safety of the leading suture passer and all-inside suture instrument (Fast-Fix). Graft status was evaluated according to the Stoller classification.

resultsBased on preoperative MRI measurements, the expected trajectory of the leading suture passer did not transect the common peroneal nerve (CPN), with the closest distance between the expected trajectory and CPN being 1.4 mm and the average distance being 6.8 ± 3.2 mm. The average distance from the lateral meniscal posterior horn (LMPH) to the popliteal neurovascular bundle (PNVB) was 7.4 ± 2.6 mm and the nearest was 4.8 mm. The expected trajectory of the all-inside suturing instrument did not transect the PNVB when the distance was at least 12 mm, from the most lateral margin of the posterior cruciate ligament (PCL). Grade 3 signal intensity in the posterior third of the allograft on MRI was observed in 6 of 35 (17.1%) patients. Amongst the grade 3 signal intensities in the posterior one-third of the allografts, 3 of the 35 (8.5%) LMATs had a distorted contour.

conclusionThe single-incision bone bridge LMAT technique introduced in this study is a convenient approach that preserves neurovascular safety and provides good results for the distortion of the posterior horn of the allograft and graft maturation. The safety zone for the penetrating devices during the procedure extended from 12 mm laterally to the most lateral margin of the PCL to the medial margin of the popliteal hiatus. LEVEL OF EVIDENCE: IV.

Indexed as

Menisci, TibialPosterior Cruciate LigamentAllograftsHumansKnee JointMagnetic Resonance ImagingTransplantation, HomologousAll-inside sutureBone bridgeKneeLateralMeniscus allograftTechniquesTransplantation

Identifiers

PMID37964127
OpenAlexW4388704131

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.