Evidence map›Paper›PMID 37963816›Full record

ArticleOrthopaedic surgery2024

Arthroscopic Bone Grafting and Robot-assisted Fixation for Scaphoid Nonunion.

Zhe Yi, Rebecca Qian Ru Lim, Wei Chen, Jin Zhu, Shanlin Chen, Bo Liu

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Efficacy analysis of arthroscopic reduction combined with orthopedic robot-guided screw placement for Hawkins type II fractures of the talus neck.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2025
    Article
  5. Review
  6. Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhe YiDepartment of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0001-7788-8165
Rebecca Qian Ru LimDepartment of Hand & Reconstructive Microsurgery, Singapore General Hospital, Singapore, Singapore.ORCID https://orcid.org/0000-0001-6244-4561
Wei ChenDepartment of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Jin ZhuDepartment of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
Shanlin ChenDepartment of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0003-1027-338X
Bo LiuDepartment of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0003-0778-1017

Funding

Beijing Municipal Science and Technology Project Z201100005520094Beijing Natural Science Foundation-Joint funds of Haidian Original innovation Project L202030National Natural Science Foundation of China 82272581Yunnan Provincial Science and Technology Talents and Platform Project 202105AF150050
6 · The paper itself

Abstract

objectivesScaphoid nonunion remains a challenging problem to manage with no general consensus on its treatment recommendations. We propose a novel minimally invasive (MIS) technique of arthroscopic bone grafting (ABG) with robot-assisted fixation for the treatment of scaphoid nonunions.

methodsPatients with radiographically proven scaphoid nonunion treated by this novel surgical technique were included. Following arthroscopic debridement and iliac crest bone grafting, the scaphoid was fixed percutaneously using either multiple Kirschner (K)-wires or a headless compression screw using a robotic navigation system.

resultsSix male patients with an average age of 29.2 years were enrolled. Four patients had scaphoid waist fractures, and the other two were proximal pole fractures. During wrist arthroscopy, punctate bleeding of the proximal scaphoid fragment was observed in four out of the six patients. Half of the patients were fixed using a headless compression screw and the other half using multiple K-wires. All the guidewires were placed with a single-attempt using the robotic navigation system. Postoperatively, all the scaphoid fractures had complete radiographic union by 16 weeks. At a mean follow-up of 18.3 months, there were significant improvements in wrist range of motion, grip strength, and patient-rated outcomes. No intraoperative or early postoperative complications were encountered in any of our patients.

conclusionArthroscopic bone grafting with robot-assisted fixation is a feasible and promising therapeutic option for scaphoid nonunions, regardless of the vascularity of the proximal pole fragment. This novel technique allows for anatomic restoration of the scaphoid alignment and accurate, targeted placement of implants into the scaphoid nonunion site within a single-attempt using a robotic navigation system.

Indexed as

Fractures, BoneFractures, UnunitedRoboticsScaphoid BoneWrist InjuriesAdultBone TransplantationFracture Fixation, InternalHumansMaleRetrospective StudiesArthroscopyFracture healingRobotic surgical proceduresScaphoid nonunionWrist injuries

Identifiers

PMID37963816
PMCPMC10782245

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.