Evidence map›Paper›PMID 37962674›Full record

ArticleAnnals of biomedical engineering2024

Electromechanical Response of Mesenteric Ischemia Defined Through Simultaneous High-Resolution Bioelectrical and Video Mapping.

Sachira Kuruppu, Leo K Cheng, Timothy R Angeli-Gordon, Recep Avci, Niranchan Paskaranandavadivel

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sachira KuruppuAuckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.
Leo K ChengAuckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.ORCID http://orcid.org/0000-0003-2426-8987
Timothy R Angeli-GordonAuckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.
Recep AvciAuckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand.
Niranchan PaskaranandavadivelAuckland Bioengineering Institute, University of Auckland, Private Bag 92019, Auckland, 1142, New Zealand. npas004@aucklanduni.ac.nz.
University of Auckland · NZ

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intestinal motility is governed in part by bioelectrical slow-waves and spike-bursts. Mesenteric ischemia is a substantial clinical challenge, but its electrophysiological and contractile mechanisms are not well understood. Simultaneous high-resolution bioelectrical and video mapping techniques were used to capture the changes in slow-waves, spike-bursts, and contractile activity during baseline, ischemia, and reperfusion periods. Experiments were performed on anesthetized pigs where intestinal contractions were quantified using surface strain and diameter measurements, while slow-wave and spike-bursts were quantified using frequency and amplitude. Slow-waves entrainment within the ischemic region diminished during ischemia, resulting in irregular slow-wave activity and a reduction in the frequency from 12.4 ± 3.0 cycles-per-minute (cpm) to 2.5 ± 2.7 cpm (p = 0.0006). At the end of the reperfusion period, normal slow-wave entrainment was observed at a frequency of 11.5 ± 2.9 cpm. There was an increase in spike-burst activity between the baseline and ischemia periods (1.1 ± 1.4 cpm to 8.7 ± 3.3 cpm, p = 0.0003) along with a spasm of circumferential contractions. At the end of the reperfusion period, the frequency of spike-bursts decreased to 2.7 ± 1.4 cpm, and contractions subsided. The intestine underwent tonal contraction during ischemia, with the diameter decreasing from 29.3 ± 2.6 mm to 21.2 ± 6.2 mm (p = 0.0020). At the end of the reperfusion period, the intestinal diameter increased to 27.3 ± 3.9 mm. The decrease in slow-wave activity, increase in spike-bursts, and tonal contractions can objectively identify ischemic segments in the intestine. It is anticipated that the use of electrophysiological slow-wave and spike-burst biomarkers, along with contractile measures, could identify mesenteric ischemia in surgical settings and allow an objective biomarker for successful revascularization.

Indexed as

Mesenteric IschemiaAnimalsGastrointestinal MotilityIntestinesIschemiaMuscle ContractionSwineIschemiaMotilityReperfusionSlow-waveSpike-burst

Identifiers

PMID37962674
OpenAlexW4388654402

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.