ArticleSensors (Basel, Switzerland)2023
Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- A standardized manual goniometry protocol to quantify joint range of motion in women with rheumatoid arthritis.MethodsX · 2026Article
- Turns and Turn-Related Falls: Stepping on a Rotating Platform as a Potential Approach to Foster Adapted Muscular and Neural Plasticity in Fragile Persons and Patients with Motor Impairment.Brain sciences · 2026Article
- Criterion Validity and Inter-Method Reliability of a Smartphone Sensor-Based Application for Lower-Limb Range of Motion: In-Person vs. Tele-Assessment.Sensors (Basel, Switzerland) · 2026Article
- Validity, reliability, and user perspectives of the newly developed joint angle measurement system: a preliminary study.Scientific reports · 2025Article
- Assessment of Elbow Proprioception with Inertial Measurement Units-Validity and Reliability Study.Sensors (Basel, Switzerland) · 2025Article
- Impact of early vs. delayed physical therapy on functional recovery, proprioception, and return to sport after anterior cruciate ligament (ACL) reconstruction: a cross-sectional study.Journal of orthopaedic surgery and research · 2025Article
- Hip Active Range of Motion in Patients with Femoroacetabular Impingement Syndrome.Sensors (Basel, Switzerland) · 2025Article
- Comparative analysis of the effects of gender on lower extremity kinematics following a 5 km running time trial in collegiate recreational runners.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Measuring joint range of motion has traditionally occurred with a universal goniometer, inclinometer, or expensive laboratory systems. The popularity of the inertial measurement unit (IMU) is growing, enabling the small and even single portable device to measure the range of motion. Until now, they were not used to assess hip joint range of motion. Our study aimed to check the validity of IMUs in assessing hip range of motion and compare them to other measurement devices-universal goniometer and inclinometer. Twenty participants completed three hip movements (flexion in standing and prone internal and external rotation) on both hips. Two testers independently assessed each movement with a goniometer, digital inclinometer, and IMU at different time points. To assess the agreement of active hip ROM between devices, Intraclass Correlation Coefficient (ICC) and Bland-Altman analysis were used. Furthermore, inter-rater and intra-rater reliability were also assessed by using ICC and Bland-Altman analysis. Limits of agreement (LOA) were calculated using Bland-Altman plots. The IMU demonstrated good to excellent validity (ICC: 0.87-0.99) compared to the goniometer and digital inclinometer, with LOAs < 9°, across all tested movements. Intra-rater reliability was excellent for all devices (ICC: 0.87-0.99) with LOAs < 7°. However, inter-rater reliability was moderate for flexion (ICC: 0.58-0.59, LOAs < 22.4) and poor for rotations (ICC: -0.33-0.04, LOAs < 7.8°). The present study shows that a single inertial measurement unit (RSQ Motion, RSQ Technologies, Poznan, Poland) could be successfully used to assess the active hip range of motion in healthy subjects, comparable to other methods accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials