ArticleJournal of clinical medicine2023
Assessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation.
Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 7 citations in OpenAlex.
- A comparative study of O-arm navigation-assisted OLIF 360 versus traditional OLIF combined with Mazor Renaissance robot-assisted posterior fixation for single-level lumbar spondylolisthesis: clinical and radiographic outcomes.Journal of orthopaedic surgery and research · 2026Article
- Influence of prone, supine, and lateral positions during spine surgery on vascular, abdominal, and postural anatomy: a comprehensive review and Bayesian meta-analysis.European journal of medical research · 2025Review
- Technique, Safety, and Accuracy Assessment of Percutaneous Pedicle Screw Placement Utilizing Computer-Assisted Navigation in Lateral Decubitus Single-Position Surgery.International journal of spine surgery · 2024Article
- A Novel Intraoperative CT Navigation System for Spinal Fusion Surgery in Lumbar Degenerative Disease: Accuracy and Safety of Pedicle Screw Placement.Journal of clinical medicine · 2024Article
- Preoperative application of CT and MRI registration in lumbar disc herniation endoscopic surgery could improve the postoperative rehabilitation of patients.American journal of translational research · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Percutaneous pedicle screws (PPSs) are commonly used in posterior spinal fusion to treat spine conditions such as trauma, tumors, and degenerative diseases. Precise PPS placement is essential in preventing neurological complications and improving patient outcomes. Recent studies have suggested that intraoperative computed tomography (CT) navigation can reduce the dependence on extensive surgical expertise for achieving accurate PPS placement. However, more comprehensive documentation is needed regarding the procedural accuracy of lateral spine surgery (LSS). In this retrospective study, we investigated patients who underwent posterior instrumentation with PPSs in the thoracic to lumbar spine, utilizing an intraoperative CT navigation system, between April 2019 and September 2023. The system's methodology involved real-time CT-based guidance during PPS placement, ensuring precision. Our study included 170 patients (151 undergoing LLIF procedures and 19 trauma patients), resulting in 836 PPS placements. The overall PPS deviation rate, assessed using the Ravi scale, was 2.5%, with a notably higher incidence of deviations observed in the thoracic spine (7.4%) compared to the lumbar spine (1.9%). Interestingly, we found no statistically significant difference in screw deviation rates between upside and downside PPS placements. Regarding perioperative complications, three patients experienced issues related to intraoperative CT navigation. The observed higher rate of inaccuracies in the thoracic spine suggests that various factors may contribute to these differences in accuracy, including screw size and anatomical variations. Further research is required to refine PPS insertion techniques, particularly in the context of LSS. In conclusion, this retrospective study sheds light on the challenges associated with achieving precise PPS placement in the lateral decubitus position, with a significantly higher deviation rate observed in the thoracic spine compared to the lumbar spine. This study emphasizes the need for ongoing research to improve PPS insertion techniques, leading to enhanced patient outcomes in spine surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.