Evidence map›Paper›PMID 37959378›Full record

ArticleJournal of clinical medicine2023

Assessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation.

Akihiko Hiyama, Daisuke Sakai, Hiroyuki Katoh, Satoshi Nomura, Masahiko Watanabe

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Akihiko HiyamaDepartment Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.ORCID 0000-0002-2474-9118
Daisuke SakaiDepartment Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.ORCID 0000-0003-4189-9270
Hiroyuki KatohDepartment Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.ORCID 0000-0003-0046-3008
Satoshi NomuraDepartment Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.
Masahiko WatanabeDepartment Orthopaedic Surgery, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.ORCID 0000-0001-9038-0446
Tokai University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Percutaneous pedicle screws (PPSs) are commonly used in posterior spinal fusion to treat spine conditions such as trauma, tumors, and degenerative diseases. Precise PPS placement is essential in preventing neurological complications and improving patient outcomes. Recent studies have suggested that intraoperative computed tomography (CT) navigation can reduce the dependence on extensive surgical expertise for achieving accurate PPS placement. However, more comprehensive documentation is needed regarding the procedural accuracy of lateral spine surgery (LSS). In this retrospective study, we investigated patients who underwent posterior instrumentation with PPSs in the thoracic to lumbar spine, utilizing an intraoperative CT navigation system, between April 2019 and September 2023. The system's methodology involved real-time CT-based guidance during PPS placement, ensuring precision. Our study included 170 patients (151 undergoing LLIF procedures and 19 trauma patients), resulting in 836 PPS placements. The overall PPS deviation rate, assessed using the Ravi scale, was 2.5%, with a notably higher incidence of deviations observed in the thoracic spine (7.4%) compared to the lumbar spine (1.9%). Interestingly, we found no statistically significant difference in screw deviation rates between upside and downside PPS placements. Regarding perioperative complications, three patients experienced issues related to intraoperative CT navigation. The observed higher rate of inaccuracies in the thoracic spine suggests that various factors may contribute to these differences in accuracy, including screw size and anatomical variations. Further research is required to refine PPS insertion techniques, particularly in the context of LSS. In conclusion, this retrospective study sheds light on the challenges associated with achieving precise PPS placement in the lateral decubitus position, with a significantly higher deviation rate observed in the thoracic spine compared to the lumbar spine. This study emphasizes the need for ongoing research to improve PPS insertion techniques, leading to enhanced patient outcomes in spine surgery.

Indexed as

intraoperative CT navigationlateral lumbar interbody fusionlateral spine surgerypercutaneous pedicle screwsprocedural accuracyspinal fusion

Identifiers

PMID37959378
PMCPMC10647313
OpenAlexW4388304898

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.