Evidence map›Paper›PMID 37958605›Full record

ArticleInternational journal of molecular sciences2023

Synergistic Enhancement of Protein Recruitment and Retention via Implant Surface Microtopography and Superhydrophilicity in a Computational Fluid Dynamics Model.

Hiroaki Kitajima, Makoto Hirota, Toshinori Iwai, Kenji Mitsudo, Juri Saruta, Takahiro Ogawa

Abstract read
In one paragraph

Article in International journal of molecular sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hiroaki KitajimaWeintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA 90095-1668, USA.ORCID 0000-0003-0347-1468
Makoto HirotaWeintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA 90095-1668, USA.ORCID 0000-0002-1231-2808
Toshinori IwaiDepartment of Oral and Maxillofacial Surgery, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama 236-0004, Kanagawa, Japan.
Kenji MitsudoDepartment of Oral and Maxillofacial Surgery, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Kanazawa-ku, Yokohama 236-0004, Kanagawa, Japan.
Juri SarutaWeintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA 90095-1668, USA.ORCID 0000-0002-7566-3330
Takahiro OgawaWeintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA 90095-1668, USA.

Funding

DIO IMPLANT Co., Ltd 2023
6 · The paper itself

Abstract

The exact mechanisms by which implant surface properties govern osseointegration are incompletely understood. To gain insights into this process, we examined alterations in protein and blood recruitment around screw implants with different surface topographies and wettability using a computational fluid dynamics (CFD) model. Compared with a smooth surface, a microrough implant surface reduced protein infiltration from the outer zone to the implant thread and interface zones by over two-fold. However, the microrough implant surface slowed blood flow in the interface zone by four-fold. As a result, compared with the smooth surface, the microrough surface doubled the protein recruitment/retention index, defined as the mass of proteins present in the area per unit time. Converting implant surfaces from hydrophobic to superhydrophilic increased the mass of protein infiltration 2-3 times and slowed down blood flow by up to two-fold in the implant vicinity for both smooth and microrough surfaces. The protein recruitment/retention index was highest at the implant interface when the implant surface was superhydrophilic and microrough. Thus, this study demonstrates distinct control of the mass and speed of protein and blood flow through implant surface topography, wettability, and their combination, significantly altering the efficiency of protein recruitment. Although microrough surfaces showed both positive and negative impacts on protein recruitment over smooth surfaces, superhydrophilicity was consistently positive regardless of surface topography.

Indexed as

Dental ImplantsHydrodynamicsOsseointegrationProstheses and ImplantsSurface PropertiesTitaniumWettabilityDental ImplantsTitaniumbone-implant integrationmicroroughosseointegrationtitanium dental and orthopedic implantUV photofunctionalization

Identifiers

PMID37958605
PMCPMC10649348

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.