Evidence map›Paper›PMID 37957622›Full record

ArticleBMC musculoskeletal disorders2023

Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position.

Penglei Chen, Wangxin Liu, Cong Wu, Pengfei Ruan, Jicheng Zeng, Weifeng Ji

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Penglei Chen *The First Clinical Medical College, Zhejiang Chinese Medical University, 310006, Hangzhou, China.
Wangxin Liu *Chuzhou Hospital of Integrated Chinese and Western Medicine, 788 Huifeng East Road, Langya District, 239000, Chuzhou, Anhui Province, China.
Cong WuThe First Clinical Medical College, Zhejiang Chinese Medical University, 310006, Hangzhou, China.
Pengfei RuanThe First Clinical Medical College, Zhejiang Chinese Medical University, 310006, Hangzhou, China.
Jicheng ZengThe First Clinical Medical College, Zhejiang Chinese Medical University, 310006, Hangzhou, China.
Weifeng JiThe First Affiliated Hospital of Zhejiang Chinese Medical University, No9,9th Street, Qiantang District, 310020, Hangzhou, Zhejiang Province, China. jiweifeng1230@163.com.

Funding

the National Natural Science Foundation of China No. 81974576
6 · The paper itself

Abstract

purposeThe position of the acetabular and femoral components is critical for stability and wear resistance. The aim of this study is to investigate whether the fluoroscopy-guided direct anterior approach in the supine position (S-DAA) is more helpful in improving the position of acetabular and femoral components than the fluoroscopy-guided direct anterior approach in the lateral decubitus position (L-DAA).

methodsA retrospective analysis of 76 cases of fluoroscopy-guided direct anterior approach total hip arthroplasty (38 cases in the S-DAA and 38 cases in the L-DAA group) was performed in one hospital from 2019 to 2021. The differences in inclination, anteversion, femoral offset (FO), global offset (GO), and leg length discrepancy (LLD) measurements during and after surgery were analyzed. The postoperative femoral offset (FO), global offset (GO), leg length discrepancy (LLD), and preoperative and postoperative Harris hip score were compared between the two groups.

resultsIn the S-DAA group, there were no significant differences in the mean intraoperative inclination angle anteversion angle, FO, GO, and LLD compared to the postoperative values, whereas in the L-DAA group, there were significant differences between the intraoperative and postoperative measurements (P < 0.001, P = 0.009, P<0.001, P<0.001 and P = 0.008, respectively). Additionally, there were significant differences in the accuracy of LLD, FO, and GO between the two groups (P < 0.001). Compared with the L-DAA group, the average differences of inclination, anteversion, LLD, FO, and GO during and after operation in the S-DAA group were smaller, and the consistency was higher. There was a significant difference in Harris hip score between the two groups at 1 week after surgery (P = 0.033). There was no significant difference in Harris hip score between 1 month and 3 months after surgery (P = 0.482 and P = 0.797, respectively).

conclusionsIn the supine group, the direct anterior approach (DAA) provides more accurate positioning of the acetabular and femoral components. However, there was no significant difference in hip joint function and activity between the two groups at follow-up.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumFluoroscopyHumansLeg Length InequalityRetrospective StudiesSupine PositionAcetabular prosthesisDirect anterior approachFluoroscopyPositionThe femoral prosthesis

Identifiers

PMID37957622
PMCPMC10644644

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked